Carbon fiber posts may have fewer failures than metal posts.

نویسنده

  • Charles J Goodacre
چکیده

SELECTION CRITERIA The authors searched MEDLINE, EMBASE, CENTRAL, and Scopus electronic databases through 2004 for eligible articles. The authors also searched International Association for Dental Research conference proceedings and abstracts from 1996-2004 and contacted manufacturers and other known experts to identify unpublished studies. Studies had to be randomized or quasi-randomized clinical trials (RCT) evaluating failures of endodontically-treated permanent teeth with different post types. This systematic review included one clinical study related to answering the primary objective, and this study involved 200 patients, 100 receiving a fiber post and 100 receiving a cast metal post. A second clinical study was included as related to a secondary objective and that study involved 117 patients, with 60 receiving a composite resin restoration as the definitive treatment after placement of a fiber post and 57 receiving a complete coverage metal ceramic crown as the definitive treatment after a fiber post had been placed. KEY STUDY FACTOR The primary treatment of interest was the type of post used, metal versus non-metal. A secondary interest was the prosthetic status of the tooth, carbon fiber post followed by a composite resin restoration versus a carbon fiber post followed by a metal ceramic crown. MAIN OUTCOME MEASURE The main measure used to evaluate treatment effectiveness for the primary objective (metal versus non-metal post) and the secondary objective (composite resin definitive restoration versus metal ceramic crown) was post failure. MAIN RESULTS Regarding the study addressing the primary objective, the fiber post resulted in fewer failures (0/97) than the conventional cast post and core system (9/98) after 4 years of clinical service. The risk ratio (RR) = 0.05, and there was a 95% confidence interval (CI) of 0.00 to 0.90. This study was judged to be at high risk of bias. Root fracture was the only failure encountered in the cast post and core group. CONCLUSIONS The results suggest fiber posts may be more successful than cast metal posts, but there were not enough RCTs to warrant a definitive recommendation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An In Vitro Comparative Evaluation of Fracture Resistance of Custom Made, Metal, Glass Fiber Reinforced and Carbon Reinforced Posts in Endodontically Treated Teeth

BACKGROUND Posts are used to enhance crown buildup in pulpless teeth with destructed crown portion. Different types of post are used in endodontically treated teeth. The aim of the present in vitro study was to evaluate fracture resistance of custom made, metal, glass fiber reinforced and carbon reinforced posts in endodontically treated teeth. MATERIALS AND METHODS An in vitro study was carr...

متن کامل

تازه هایی در مورد پست و کور و پست های غیر فلزی

Many different methods are suggested to restore endodontically treated teeth. Prefabricated posts can not be indicated for all teeth and cast posts require extra time and cost. In addition, with the introduction of full ceramic restorations, achieving the ideal esthetic with metal post underneath them may be problematic or impossible because the darkness of the metallic posts may show through t...

متن کامل

Flexural modulus, flexural strength, and stiffness of fiber-reinforced posts.

BACKGROUND The radiopacity degree of posts is not enough for adequate visualization during radiographic analyses. Glass fiber post with stainless steel reinforcement has been fabricated in an attempt to overcome this limitation. AIM This study was designed to determine the influence of this metal reinforcement on the post mechanical properties. MATERIALS AND METHODS This study evaluated fle...

متن کامل

Morphological Analysis of Glass, Carbon and Glass/carbon Fiber Posts and Bonding to Self or Dual-cured Resin Luting Agents

OBJECTIVE The aim of this study was to evaluate the morphology of glass (GF), carbon (CF) and glass/carbon (G/CF) fiber posts and their bond strength to self or dual-cured resin luting agents. MATERIAL AND METHODS Morphological analysis of each post type was conducted under scanning electron microscopy (SEM). Bond strength was evaluated by microtensile test after bisecting the posts and re-bo...

متن کامل

Fiber Post Clinical Studies.pages

conclusions: The restoration of root canal treated teeth – because of the significant loss of tooth structureis often achieved with post and core. However, posts may generate stresses, which lead to vertical root fracture and the loss of the tooth. Since post design, materials used and post space preparation has significant influence on vertical fracture prevalence, broad investigation is in pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of evidence-based dental practice

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2010