Dove prism based rotating dual beam bidirectional Doppler OCT

نویسندگان

  • Cedric Blatter
  • Séverine Coquoz
  • Branislav Grajciar
  • Amardeep S. G. Singh
  • Marco Bonesi
  • René M. Werkmeister
  • Leopold Schmetterer
  • Rainer A. Leitgeb
چکیده

Traditional Doppler OCT is highly sensitive to motion artifacts due to the dependence on the Doppler angle. This limits its accuracy in clinical practice. To overcome this limitation, we use a bidirectional dual beam technique equipped with a novel rotating scanning scheme employing a Dove prism. The volume is probed from two distinct illumination directions with variable controlled incidence plane, allowing for reconstruction of the true flow velocity at arbitrary vessel orientations. The principle is implemented with Swept Source OCT at 1060nm with 100,000 A-Scans/s. We apply the system to resolve pulsatile retinal absolute blood velocity by performing segment scans around the optic nerve head and circumpapillary scan time series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography

PURPOSE There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breath...

متن کامل

Development of a scanning head for laser Doppler vibrometry (LDV) using dual optical wedges.

A new laser Doppler vibrometry scanning head is proposed based on a pair of rotating optical wedges. A comprehensive mathematical model is developed and used to demonstrate how the wedges can be configured to scan point-by-point, in a line, in a circle, and in a combination of the two such that a straight line scan could be performed on a structure during rotation. Inevitable misalignments are ...

متن کامل

How a Dove prism transforms the orbital angular momentum of a light beam.

It is generally assumed that a light beam with orbital angular momentum (OAM) per photon of lh, is transformed, when traversing a Dove prism, into a light beam with OAM per photon of -lh. In this paper, we show theoretically and experimentally that this OAM transformation rule does not apply for highly focused light beams. This result should be taken into account when designing classical and qu...

متن کامل

An all-fiber-optic endoscopy platform for simultaneous OCT and fluorescence imaging

We present an all-fiber-optically based endoscope platform for simultaneous optical coherence tomography (OCT) and fluorescence imaging. This design entails the use of double-clad fiber (DCF) in the endoscope for delivery of OCT source and fluorescence excitation light while collecting the backscattered OCT signal through the single-mode core and fluorescence emission through the large inner cl...

متن کامل

Interstitial Doppler optical coherence tomography.

Doppler optical coherence tomography (OCT) can image tissue structure and blood flow at micrometer-scale resolution but has limited imaging depth. We report a novel, linear-scanning, needle-based Doppler OCT system using angle-polished gradient-index or ball-lensed fibers. A prototype system with a 19-guage (diameter of approximately 0.9 mm) echogenic needle is constructed and demonstrates in v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2013