Pacemaker assessment in the ambulant patient.

نویسندگان

  • A Murray
  • R S Jordan
  • R G Gold
چکیده

A new technique for assessing implanted cardiac pacemaker function in the ambulant patient has been introduced and assessed. A modified portable electrocardiograph recorder is used to store 24 hours of electrocardiograms along with marker pulses indicating the timing of pacemaker impulses. The recorder detects this narrow impulse and records a wider marker pulse on a second channel. The false positive detection rate was estimated from recordings, each of 24 hours, taken from 10 patients. All of these patients were ambulant and none had a cardiac pacemaker. There was on average less than one false positive per 24 hours. When similar recordings were taken from a group of 15 patients with pacemakers, the average false positive rate in 13 of these patients was also less than on per 24 hours. In the two other recordings artefacts resulted in false positive rates of 28 and 960 per 24 hours. Failure to detect pacemaker pulses was confirmed in only one patient. In addition to determining the accuracy of pacemaker pulse detection, the clinical usefulness of this technique was assessed. Two patients had fixed-rate pacemakers and 13 had demand pacemakers. Of the latter, two patients had a total of three episodes of failure to sense, one patient frequently failed to capture, and six patients had episodes of inappropriate inhibition of the pacemaker, the number of episodes ranging from one to 21 in 24 hours. Paced complexes were easily identified even when they occurred as fusion complexes. The frequency of paced complexes was quantified in each patient and varied from 21 to over 100 000 impulses in the 24 hour period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

ffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site

Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...

متن کامل

بررسی نیازهای آموزشی مراقبت از خود بیماران درای دستگاه ضربان ساز دائم در بیمارستان قلب شهید رجائی در سال 73-1372

A field study was made to investigate the learning needs of patients with pacemaker in Shahid Rajaii Heart Hospital's out-patient clinic (1994). A total of 60 patients with pacemaker were selected sequentially from the total population that had a pacemaker and attended the out-patient clinic in shahid Rajaii Hospital. The subjects met the criteria for participating in this study. The tool was a...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 46 5  شماره 

صفحات  -

تاریخ انتشار 1981