Detection of protease activity using a fluorescence-enhancement globular substrate.

نویسندگان

  • E W Voss
  • C J Workman
  • M E Mummert
چکیده

Bovine serum albumin (BSA) highly derivatized with fluorescein isothiocyanate (FITC, isomer I) served as a fluorescent enhancement substrate to measure protease activity. In the native globular BSA structure, the fluorescence of the lysine-conjugated fluorescein moieties was quenched 98%. Proteolytic digestion of highly derivatized BSA with Pronase resulted in fluorescence enhancement of 4300%. Both alpha-chymotrypsin and proteinase K yielded lower but similar fluorescence enhancement values of 2880% and 2800%, respectively. Digestion of the fluorescein-BSA substrate with trypsin, which required basic amino acids for activity, showed fluorescence enhancement of 1480% reflecting the fluorescein-lysine thiocarbamyl linkage. When derivatized substrate was pretreated with a thiol-reducing agent prior to incubation with proteases, a relatively small increase in fluorescence was noted relative to the untreated substrate except in the case of Pronase. The minimum sensitivity of proteolytic activity, based on a comparison of untreated and reduced FITC25BSA was 32 x 10(-6) units for I ng proteinase K, 1 x 10(-3) units for 1 ng alpha-chymotrypsin and 10 x 10(-3) units for Pronase and trypsin (1 ng each). The fluorescence enhancement assay was suited for sensitive intensity measurements or as an endpoint assay to detect protease activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Neuraminidase Activity in Pseudomonas aeruginosa PAO1

Objective(s) Some properties of neuraminidase produced by Pseudomonas aeruginosa PAO1 growth in a defined medium (BHI) were examined and evaluated for its features. Materials and Methods The obtained supernatant enzyme of P. aeruginosa PAO1 cultures was used in a sensitive fluorometric assay by using 2'-(4-methylumbelliferyl) a-D-N acetylneuraminic acid as substrate. As hydrolyzing MUN with ...

متن کامل

Use of the protease fluorescent detection kit to determine protease activity.

The Protease Fluorescent Detection Kit provides ready-to-use reagents for detecting the presence of protease activity. This simple assay to detect protease activity uses casein labeled with fluorescein isothiocyanate (FITC) as the substrate. Protease activity results in the cleavage of the FITC-labeled casein substrate into smaller fragments, which do not precipitate under acidic conditions. Af...

متن کامل

Calpain Activity Increases in Hepatocytes Following Addition

Our aim was to measure calpain protease activity during increases in cytosolic free calcium (Ca2+J after addition of extracellular ATP. The calpain protease substrate t-butoxycarbonyl-Leu-Met-7-amino-4-chloromethylcoumarin was synthesized. Nonfluorescent tbutoxycarbonyl-Leu-Met-7-amino-4-chloromethylcoumarin diffuses into the cell where it is conjugated to glutathione forming t-butoxycarbonyl-L...

متن کامل

Digestive alkaline proteases from the Tunisian barbell (Barbus callensis): Characterization and application as a detergent additive, in chicken feather-degradation and as a dehairing agent

Alkaline crude enzymes from the viscera of the Tunisian barbel (Barbus callensis) were extracted and characterized. Proteolytic crude extract from barbel viscera was active and stable in alkaline solution. The optimum pH and temperature were 11.0 and 55 °C, respectively, using casein as a substrate. The crude alkaline protease was extremely stable in the pH range of 5.0-12.0. Zymography activit...

متن کامل

Morpholinecarbonyl-Rhodamine 110 based substrates for the determination of protease activity with accurate kinetic parameters.

Commonly used fluorogenic substrate analogues for the detection of protease activity contain two enzyme-cleavable bonds conjugated to the fluorophore. Enzymatic cleavage follows a two-step reaction with a monoamide intermediate. This intermediate shows fluorescence at the same wavelength as the final product complicating the kinetic analysis of fluorescence-based assays. Fluorogenic substrate a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 1996