Committee Opinion No 689: Delivery of a Newborn With Meconium-Stained Amniotic Fluid.

ثبت نشده
چکیده

In 2006, the American Academy of Pediatrics and the American Heart Association published the 2005 guidelines on neonatal resuscitation. Before the 2005 guidelines, management of a newborn with meconium-stained amniotic fluid included suctioning of the oropharynx and nasopharynx on the perineum after the delivery of the head but before the delivery of the shoulders. The 2005 guidelines did not support this practice because routine intrapartum suctioning does not prevent or alter the course of meconium aspiration syndrome in vigorous newborns. However, the 2005 guidelines did support intubation of the trachea and suctioning of meconium or other aspirated material from beneath the glottis in nonvigorous newborns. In 2015, the guidelines were updated. Routine intubation and tracheal suctioning are no longer required. If the infant is vigorous with good respiratory effort and muscle tone, the infant may stay with the mother to receive the initial steps of newborn care. If the infant born through meconium-stained amniotic fluid presents with poor muscle tone and inadequate breathing efforts, the initial steps of resuscitation should be completed under the radiant warmer. Appropriate intervention to support ventilation and oxygenation should be initiated as indicated for each infant. Infants with meconium-stained amniotic fluid should no longer routinely receive intrapartum suctioning, whether they are vigorous or not. In addition, meconium-stained amniotic fluid is a condition that requires the notification and availability of an appropriately credentialed team with full resuscitation skills, including endotracheal intubation. Resuscitation should follow the same principles for infants with meconium-stained fluid as for those with clear fluid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ACOG Committee Opinion No. 379: Management of delivery of a newborn with meconium-stained amniotic fluid.

In accordance with the new guidelines from the American Academy of Pediatrics and the American Heart Association, all infants with meconium-stained amniotic fluid should no longer routinely receive intrapartum suctioning. If meconium is present and the newborn is depressed, the clinician should intubate the trachea and suction meconium and other aspirated material from beneath the glottis.

متن کامل

Meconium aspiration syndrome in neonates

Perhaps the most significant changes in airway management over the recent years have been in the management of an infant delivered through meconium- stained amniotic fluid( MSAF). MSAF occurs in approximately 10℅ to 20℅ of all deliveries and increases to over 30℅ in deliveries after 42 weeks gestation. Meconium aspiration syndrome ( MAS) occurs in about 2℅ to 5℅ of these cases with a high morta...

متن کامل

Comparison of Neonatal Outcome with Meconium-Stained Amniotic Fluid in Normal Vaginal Delivery and Cesarean Section

Background and Objectives: Given the consequences and serious dangers, which threatens neonates born with meconium-stained amniotic fluid, and also due to the high prevalence of cesarean section, the present research was carried out with the aim of comparing the outcomes of neonates with meconium - stained amniotic fluid in vaginal delivery and cesarean section.   Methods: The present study wa...

متن کامل

Study of prognostic factors for meconium-stained amniotic fluid

Introduction: meconium is the thick, Green - Black, with a bad odor material,  that founded around the third month of pregnancy in the intestines of fetus. 8 to 15 percent of infants has the evidence of meconium stained fluid at birth. In this study the factors affecting maternal and neonatal meconium-stained amniotic fluid be examined. Methods: This study was done in the Vali-e- asr hospital ...

متن کامل

The Comparison of Maternal Endometritis in Meconium – Stained Amniotic Fluid and Clear Amniotic Fluid

Introduction: Metritis is one of the causes of maternal morbidity and there are many risk factors for it. Because of the importance of possible association of meconium-stained amniotic fluid and maternal metritis the present study was done to determine whether meconium stained amniotic fluid (MSAF) is associated with puerperal infection. Methods: In this case-control study 150 women with MSAF a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obstetrics and gynecology

دوره 129 3  شماره 

صفحات  -

تاریخ انتشار 2017