Determination of cadmium in water by ICP-AES with on-line adsorption preconcentration using DPTH-gel and TS-gel microcolumns.

نویسندگان

  • M Zougagh
  • A García de Torres
  • J M Cano Pavón
چکیده

Two flow injection inductively coupled plasma atomic emission spectrometric methods for the preconcentration and determination of trace amounts of cadmium in sea-water and waste-water samples are described based on the adsorption of the metal ion on a micro-column placed in the injection valve of the FI manifold and packed with silica gel funtionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbohydrazide (DPTH-gel) and silica gel functionalised with methylthiosalicylate (TS-gel), respectively. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES are evaluated. The DPTH-gel preconcentration method has a linear calibration range from 5 to at least 100 ng ml(-1) of cadmium, with a R.S.D. of 1.1% for ten independent analyses of 100 ng ml(-1), a detection limit of 1.1 ng ml(-1) and a throughput of 40 samples per hour using a 60 s preconcentration time. The TS-gel preconcentration method shows a linear range between 10 and 100 ng ml(-1), with a R.S.D. of 2.5% for ten independent analyses of 100 ng ml(-1), a detection limit of 4.3 ng ml(-1) and a sample throughput of 24 samples per hour for a preconcentration time of 120 s. Validation was carried out against a certified reference water sample and by determining the analyte content in spiked synthetic sea-water, sea-water and waste-water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line preconcentration and determination of cobalt by DPTH-gel chelating microcolumn and flow injection inductively coupled plasma atomic emission spectrometry.

This paper reports the development of a new methodology for the determination of cobalt in biological samples by using a flow injection system with loaded DPTH-gel as solid phase to preconcentrate analytes. The procedure is based on the on-line preconcentration of cobalt on a microcolumn of 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The trapped cobal...

متن کامل

Automatic on line preconcentration and determination of lead in water by ICP-AES using a TS-microcolumn.

A simple, sensitive, low-cost and rapid, flow injection system for the on-line preconcentration of lead by sorption on a microcolumn packed with silica gel funtionalized with methylthiosalicylate (TS-gel) was developped. The metal is directly retained on the sorbent column and subsequently then eluted from it by EDTA. Five variables (sample flow rate, eluent flow rate, eluent concentration, pH ...

متن کامل

Preconcentration of rare earth elements on silica gel loaded with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one prior to their determination by ICP-AES.

A new chelating resin, silica gel loaded with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP), was prepared and used for the preconcentration of trace amounts of rare earth elements (REEs) in water samples prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). REEs (La, Eu, Yb and Y) were quantitatively retained on the column packed with modified sili...

متن کامل

Preconcentration of Cadmium in Environmental Samples by Cloud Point Extraction and Determination by FAAS

Cloud point extraction (CPE) has been used for the preconcentration of cadmium, after the formation of a complex with 1, 5-bis(di-2-pyridylmethylene) thiocarbonohydrazide (DPTH), and further determination by flame atomic absorption spectrometry (FAAS) using Triton X-114 as surfactant. The main factors affecting the CPE, such as concentration of Triton X-114 and DPTH, pH, equilibration temperatu...

متن کامل

Automated on-line separation preconcentration system for palladium determination by graphite furnace atomic absorption spectrometry and its application to palladium determination in environmental and food samples.

A flow injection (FI) system was used to develop an efficient on-line sorbent extraction preconcentration system for palladium by graphite furnace atomic absorption spectrometry (GFAAS). The investigated metal was preconcentrated on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The palladium is eluted with 40mul of HCl 4M and d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2002