Second-harmonic generation imaging of membrane potential with photon counting.

نویسندگان

  • Jiang Jiang
  • Rafael Yuste
چکیده

Second-harmonic generation (SHG) can be used for imaging membrane potential in neurons, but poor signal-to-noise (S/N) limits accurate measurements of small voltage transients. We use photon counting to improve the S/N of weak SHG signal detection. Photon counting generates shot-noise limited and integrable signals, eliminates pulse-to-pulse variation, and built-in discriminators reduces the background to practically zero. In single trials, by using photon counting, we obtain a more than a twofold S/N increase over analog voltage detection. Trial-to-trial variability is also reduced by 50%. Finally, we show that, using photon counting, the kinetics of fast events such as action potentials can be recorded more accurately.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity of second harmonic generation from styryl dyes to transmembrane potential.

In this article we present results from the simultaneous nonlinear (second harmonic generation and two-photon excitation fluorescence) imaging and voltage clamping of living cells. Specifically, we determine the sensitivity to transmembrane potential of second harmonic generation by ANEP-chromophore styryl dyes as a function of excitation wavelength and dye structure. We have measured second ha...

متن کامل

Second harmonic imaging of membrane potential of neurons with retinal.

We present a method to optically measure and image the membrane potential of neurons, using the nonlinear optical phenomenon of second harmonic generation (SHG) with a photopigment retinal as the chromophore [second harmonic retinal imaging of membrane potential (SHRIMP)]. We show that all-trans retinal, when adsorbed to the plasma membrane of living cells, can report on the local electric fiel...

متن کامل

Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy: errata.

We demonstrate that simultaneous second-harmonic generation (SHG) and two-photon-excited fluorescence (TPEF) can be used to rapidly image biological membranes labeled with a styryl dye. The SHG power is made compatible with the TPEF power by use of near-resonance excitation, in accord with a model based on the theory of phased-array antennas, which shows that the SHG radiation is highly structu...

متن کامل

Membrane potential detection with second-harmonic generation and two-photon excited fluorescence: A theoretical comparison

We theoretically compare the performance of TPEF and SHG microscopy for membrane potential imaging. We argue that electrochromic TPEF and SHG membrane potential responses are reflections of the same phenomenon, and can be described in a unified manner as resulting from the linear Stark effect. We also show that TPEF and SHG exhibit similar sensitivities in the case of both electrochromic and or...

متن کامل

Optical recording of action potentials with second-harmonic generation microscopy.

Nonlinear microscopy has proven to be essential for neuroscience investigations of thick tissue preparations. However, the optical recording of fast (approximately 1 msec) cellular electrical activity has never until now been successfully combined with this imaging modality. Through the use of second-harmonic generation microscopy of primary Aplysia neurons in culture labeled with 4-[4-(dihexyl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2008