A clinical comparison between DisCoVisc and 2% hydroxypropylmethylcellulose in phacoemulsification: a fellow eye study

نویسندگان

  • Rodrigo F. Espíndola
  • Emerson F.S. Castro
  • Marcony R. Santhiago
  • Newton Kara-Junior
چکیده

OBJECTIVE This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Prospective randomized trial comparing Discovisc versus Healon in phacoemulsification].

OBJECTIVE To compare the intraoperative behaviour of both, DisCoVisc and Healon used as viscoelastics in cataract surgery. METHOD We prospectively evaluated 35 patients with cataracts who underwent phacoemulsification and intraocular lens implantation. Patients were randomized into two groups. Group A included 17 patients in where Healon was used as a viscoelastic, whereas group B included 18...

متن کامل

Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery

PURPOSE To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc) with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc). PATIENTS AND METHODS In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmaske...

متن کامل

The influence of viscoelastic substances on the corneal endothelium during cataract surgery by phacoemulsification.

PURPOSE To compare the ability of different ophthalmic viscoelastic devices to protect the corneal endothelium following in-the-bag phacoemulsification with posterior chamber intraocular lens (IOL) implantation. MATERIAL & METHODS We studied 50 patients with soft to moderately dense (Grade 1-3) cataract and corneal endothelial cell density of >2000 cells/mm2. The corneal response to surgery w...

متن کامل

Comparison of surgically induced astigmatism between one-handed and two-handed cataract surgery techniques

BACKGROUND The purpose of this study was to compare surgically induced astigmatism (SIA) between one-handed and two-handed cataract surgery techniques. METHODS Eighty-eight eyes of 44 patients with no ocular disease other than cataract, who underwent cataract surgery by a single surgeon, were selected for this study. Cataract surgery was performed by coaxial phacoemulsification and intraocula...

متن کامل

Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period

PURPOSE To compare the effect of two ocular viscosurgical devices (OVDs) on intraocular pressure (IOP) and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model) implantation. METHODS A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC) in one eye and 1% hyaluronic acid in fellow eye. Time ta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 67  شماره 

صفحات  -

تاریخ انتشار 2012