Current Measurement with Optical Current Transformer. J World Elec. Eng. Tech., 4 (1): 29-35

نویسنده

  • Omid Alavi
چکیده

The development of power electrical systems causes attention to accuracy of protection elements and measurement values. So we need some new measuring devices with high accuracy for power transmission lines. One of these devices is Optical Current Transformer (OCT). Optical current transformers are suitable for power system protection and can replace the magnetic current transformers. In this paper, we described a comparison between optical current transformers and conventional current transformers. Using an optical current transformer has several advantages, e.g. high accuracy, low weight, easy installation and no-saturation. But it has some disadvantages also, like if the magnetic fields induced by the currents through other conductors is sufficiently high, the fault current measured will have some errors. In general, the optical current transformer device is more reliable and suitable for new power systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Design of Bearingless Permanent Magnet-Type Synchronous Motors for Generating Maximum Levitation Force. J World Elec. Eng. Tech., 4 (1): 07-12

One maintenance task that still exist with conventional motors, are bearing lubrication and renewal. Bearingless motors are replaced with conventional motor that uses a magnetic levitation force to suspend a rotor without any mechanical contact. In bearingless motors, additional windings are wound together with motor windings in stator slots. In this paper, a bearingless permanent magnet-type s...

متن کامل

Convolutional source encoding

[l] J. M. Wozencraft , “Sequential decoding for reliable communication,” SC. D. dissertation, Dep. Elec. Eng., M.I.T., Cambridge, June 1957. [2] A. J. Viterbi, “Error bounds for convolutional codes and an asymptotically opt imum decoding algorithm,” IEEE Trans. Inform. Theory, vol. IT-13, pp. 260-269, Apr. 1967. [3] R. G. Gallager, Information Theory and Reliable Communicat ion. New York: W ile...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

Mitigation Transformer Inrush Current Using Modified Transient Current Limiter

This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...

متن کامل

Nanosecond - Current Probe for High Voltage Experiments

A current probe has been designed which allows measurement of ns;pulsed currents in high voltage environments. The probe consists of a current transformer and an optical transducer. The transformer coil in a metallic torus is considered as a slow-wave transmission line and is terminated with its wave impedance. In this mode of operation current pulses shorter than twice the transit time of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015