Computerized detection of cerebral emboli and discrimination from artifact using Doppler ultrasound.

نویسندگان

  • H Markus
  • A Loh
  • M M Brown
چکیده

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can detect circulating cerebral emboli. Monitoring of patients with potential embolic sources may allow identification of high-risk patients who can then be selected for prophylactic treatment. However, practical patient monitoring will require automated programs that can detect emboli and differentiate them from artifact. METHODS A new off-line algorithm for the detection of emboli, which detects the characteristic relative power increase occurring with an embolus, was evaluated in both an animal model and in patients. (1) In a sheep model, solid embolic materials (thrombus, platelet aggregates, and atheroma) were introduced into the proximal carotid artery while the distal carotid artery or a major branch was insonated. The signals resulting from 77 emboli (mean size, 1.77 mm) were studied and compared with the Doppler signals resulting from artifact. (2) In patients, 100 embolic signals occurring in three patients were analyzed and compared with signals associated with artifact in the same patients. RESULTS (1) In the sheep model, emboli resulted in a short-duration, high-intensity signal, but intensity increase alone did not distinguish between emboli and artifact. In contrast, the algorithm discriminated embolus from artifact with a sensitivity of 98.7% and a specificity of 98.0%. (2) In patient studies, embolic signals were differentiated from artifact with a sensitivity of 97.2% and a specificity of 97.0% by the algorithm. CONCLUSIONS Using such an algorithm, detection of cerebral emboli and discrimination from artifact are possible with a high sensitivity and specificity. Incorporation of such an algorithm into an on-line system should make prolonged patient monitoring practical.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of arterial emboli using Doppler ultrasound in rabbits.

The purpose of this study was to develop an animal model that could be used to test the ability of Doppler ultrasound to detect arterial emboli composed of materials that are often involved in cerebral emboli. Emboli introduced into the rabbit aorta via the left renal artery consisted of clotted whole blood, platelets, atheromatous material, fat, or air. The ultrasound examination was carried o...

متن کامل

An emboli detection system based on Dual Tree Complex Wavelet Transform and ensemble learning

The traditional visual and acoustic embolic signal detection methods based on the expert analysis of individual spectral recordings and Doppler shift sounds are the gold standards. However, these types of detection methods are high-cost, subjective, and can only be applied by experts. In order to overcome these drawbacks, computer based automated embolic detection systems which employ spectral ...

متن کامل

Doppler Emboli in Acute Stroke 383 Middle Cerebral Artery Doppler Emboli Signals in 45 Patients With Ischemic Stroke

Background and Purpose Doppler ultrasound detection of emboli signals may assist in distinguishing erabolic from thrombotic stroke. Selected patient groups have a high incidence of such signals. We have examined consecutive stroke cases to identify the incidence of Doppler emboli in different etiologic subtypes of stroke. Methods Forty-five patients presenting with first-ever acute carotid terr...

متن کامل

Doppler Emboli in Acute Stroke 383 Middle Cerebral Artery Doppler Emboli Signals

Background and Purpose Doppler ultrasound detection of emboli signals may assist in distinguishing erabolic from thrombotic stroke. Selected patient groups have a high incidence of such signals. We have examined consecutive stroke cases to identify the incidence of Doppler emboli in different etiologic subtypes of stroke. Methods Forty-five patients presenting with first-ever acute carotid terr...

متن کامل

Can transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.

BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 24 11  شماره 

صفحات  -

تاریخ انتشار 1993