Stability of standard curves prepared for EMIT homogeneous enzyme immunoassay kits stored at room temperature after reconstitution.

نویسندگان

  • P R Bach
  • J W Larsen
چکیده

We examined the stability of standard curves obtained with use of homogeneous enzyme immunoassay reagents (EMIT; Syva Corp., Palo Alto, CA) for assay of lidocaine, procainamide, N-acetylprocainamide, gentamicin, and theophylline, when stored at room temperature (23-24 degrees C) after reconstitution of the lyophilized materials. Standards were run and curves obtained for as long as 16 days after reconstitution. All standard curves were acceptable, according to the criteria specified in Syva product literature. Absorbance changes for all calibrators, including the zero calibrator, increased gradually with time. Increases of non-zero calibrators were largely offset by a parallel increase in the zero calibrator, such that the quantity delta A--delta A0 was very nearly constant with time. Standard curves based on the quantity delta A--delta A0 can be used for longer than curves based only on delta A.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ligand displacement immunoassay: a novel enzyme immunoassay demonstrated for measuring theophylline in serum.

We describe a ligand displacement immunoassay for measurement of theophylline in serum or plasma and show it to be clinically useful. A conjugate of theophylline-specific antiserum covalently bound to micro-crystalline cellulose and a beta-galactosidase-labeled theophylline derivative is prepared as a lyophilized reagent. Sample is added to the conjugate and, after 5-min incubation at room temp...

متن کامل

Enzyme immunoassay of gentamicin with use of a centrifugal analyzer.

Gentamicin was determined in serum by the homogeneous enzyme immunoassay system (EMIT) adapted to the Multistat centrifugal analyzer. The standard curve can be extended to 16 mg/L; however, poor precision is obtained at concentrations greater than 10 mg/L because a small difference in change in absorbance there will produce a significant variation in gentamicin concentration. For example, the w...

متن کامل

Enzyme immunoassay and enzyme inhibition assay of methotrexate, with use of the centrifugal analyzer.

Methotrexate was determined by the homogeneous enzyme immunoassay (EMIT) with the Multistat and CentrifiChem centrifugal analyzers and by the enzyme inhibition assay with use of the Multistat centrifugal analyzer. With both methods, the standard curve extends from 0.2 to 2.0 mumol/L and there is no interference from bilirubin in concentrations up to 100 mg/L. Moderately lipemic samples do not i...

متن کامل

Statistical analysis of the stability of the standard curve for some Syva EMIT assays.

Derivation of standard curves for the EMIT therapeutic drug monitoring system involves several mathematical algorithms, all of which can be rewritten in the form of a linear equation y = mx + b. We examined the stability of the standard curve in terms of slope and y-intercept for three drug assays (procainamide, gentamicin, and carbamazepine) by generating calibration curves intermittently for ...

متن کامل

The Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods

Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 1980