Joint registry approach for identification of outlier prostheses

نویسندگان

  • Richard N de Steiger
  • Lisa N Miller
  • David C Davidson
  • Philip Ryan
  • Stephen E Graves
چکیده

BACKGROUND AND PURPOSE Joint Replacement Registries play a significant role in monitoring arthroplasty outcomes by publishing data on survivorship of individual prostheses or combinations of prostheses. The difference in outcomes can be device- or non-device-related, and these factors can be analyzed separately. Although registry data indicate that most prostheses have similar outcomes, some have a higher than anticipated rate of revision when compared to all other prostheses in their class. This report outlines how the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) has developed a method to report prostheses with a higher than expected rate of revision. These are referred to as "outlier" prostheses. MATERIAL AND METHODS Since 2004, the AOANJRR has developed a standardized process for identifying outliers. This is based on a 3-stage process consisting of an automated algorithm, an extensive analysis of individual prostheses or combinations by registry staff, and finally a meeting involving a panel from the Australian Orthopaedic Association Arthroplasty Society. Outlier prostheses are listed in the Annual Report as (1) identified but no longer used in Australia, (2) those that have been re-identified and that are still used, and (3) those that are being identified for the first time. RESULTS 78 prostheses or prosthesis combinations have been identified as being outliers using this approach (AOANJRR 2011 Annual Report). In addition, 5 conventional hip prostheses were initially identified, but after further analysis no longer met the defined criteria. 1 resurfacing hip prosthesis was initially identified, subsequently removed from the list, and then re-identified the following year when further data were available. All unicompartmental and primary total knee prostheses identified as having a higher than expected rate of revision have continued to be re-identified. INTERPRETATION It is important that registries use a transparent and accountable process to identify an outlier prosthesis. This paper describes the development, implementation, assessment, and impact of the approach used by the Australian Registry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A statistical test for outlier identification in data envelopment analysis

In the use of peer group data to assess individual, typical or best practice performance, the effective detection of outliers is critical for achieving useful results. In these ‘‘deterministic’’ frontier models, statistical theory is now mostly available. This paper deals with the statistical pared sample method and its capability of detecting outliers in data envelopment analysis. In the prese...

متن کامل

Local multivariate outliers as geochemical anomaly halos indicators, a case study: Hamich area, Southern Khorasan, Iran

Anomaly recognition has always been a prominent subject in preliminary geochemical explorations. Among the regional geochemical data processing, there are a range of statistical and data mining techniques as well as different mapping methods, which serve as presentations of the outputs. The outlier’s values are of interest in the investigations where data are gathered under controlled condition...

متن کامل

National Joint Registry of Iran

Joint replacement is currently on the rise with a high community burden. A registry was designed to evaluate the costs,possible complications, and rate of revisions as well as finding the most effective techniques, risk factors associatedwith poor results, indications for revision surgeries, and also demographic evaluation of patients undergoing jointreplacement surgery in Iran. Level of eviden...

متن کامل

Five-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry.

BACKGROUND Articular Surface Replacement (ASR) hip prostheses, which have metal-on-metal bearing surfaces, were manufactured by DePuy Orthopaedics (Warsaw, Indiana) for use in both conventional total hip arthroplasty and hip resurfacing. Both the ASR XL Acetabular System and the ASR Hip Resurfacing System were recently recalled worldwide by the manufacturer. This report summarizes an analysis b...

متن کامل

Identification of outliers types in multivariate time series using genetic algorithm

Multivariate time series data, often, modeled using vector autoregressive moving average (VARMA) model. But presence of outliers can violates the stationary assumption and may lead to wrong modeling, biased estimation of parameters and inaccurate prediction. Thus, detection of these points and how to deal properly with them, especially in relation to modeling and parameter estimation of VARMA m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 84  شماره 

صفحات  -

تاریخ انتشار 2013