Caliper vs. Lipometer--Comparing Two Methods of Subcutaneous Body Fat Measurement by Bland-Altman Diagrams.

نویسندگان

  • Erwin Tafeit
  • Petra Silke Kaimbacher
  • Sandra Johanna Wallner-Liebmann
  • Gilbert Reibnegger
  • Gerhard Cvirn
  • Jaak Jürimäe
  • Meeli Saar
  • Jarek Maestu
  • Priit Purge
  • Evelin Lätt
  • Toivo Jürimäe
چکیده

Skinfold Calipers are widely used to obtain subcutaneous adipose tissue thickness because of its non-invasive, simple and inexpensive technique. Nevertheless, Caliper skinfold thicknesses have the disadvantage of measuring compressed adipose tissue and double layers of skin, which might reduce the precision of these results. In contrast, the computerized optical device Lipometer was developed to permit a quick, precise and non-invasive determination of non-compressed mono layers of subcutaneous adipose tissue thickness. In the present paper we investigate the hypothesis that Caliper skinfold thicknesses are significantly different from subcutaneous adipose tissue thicknesses in mm, which can be measured by Lipometer. Caliper and Lipometer results were obtained from 371 Estonian boys aged between 9.0 and 12.8 years. Measurements were performed at six different body sites: triceps, biceps, upper back, upper abdomen, hip and front thigh. Caliper measurements were systematically higher than Lipometer results in a range between 1.2 mm (hip) and 11.08 mm (front thigh). The limits of agreement analysis provided intervals from 7.5 mm (biceps) up to 30.14 mm (front thigh). Comparing Caliper and Lipometer results very low measurement agreement was found. The two methods provided very poor interchangeability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does impedance measure a functional state of the body fat?

The aim was to compare methods of body fat measurement in different BMI groups. An additional aim was to discuss differences reflecting the structural and functional changes of fat tissue. The study group included 130 adult Caucasian women stratified by body mass index (BMI): 18-24.99 (n=30), 25-29.99 (n=26), 30-34.99 (n=33), 35-39.99 (n=30), and BMI>/=40 (n=11). Bioelectrical impedance was per...

متن کامل

Estimating DXA total body fat percentage by lipometer subcutaneous adipose tissue thicknesses.

DXA is an accepted reference method to estimate body composition. However several difficulties in the applicability exist. The equipment is rather expensive, not portable, impractical for measurement of big study populations and it provides a minimal amount of ionizing radiation exposure. The optical device Lipometer (EU Pat.No. 0516251) provides non-invasive, quick, precise and safe measuremen...

متن کامل

Suprailiac or abdominal skinfold thickness measured with a skinfold caliper as a predictor of body density in Japanese adults.

Measurement of subcutaneous fat thickness with a skinfold caliper is a simple and inexpensive technique for assessment of body composition, but is influenced by the skin site or the obesity level. The resulting measurement errors may influence the prediction accuracy of body density. We therefore aimed to clarify the characteristics of measurement errors with a skinfold caliper and to determine...

متن کامل

Subcutaneous fat patterns in type-2 diabetic men and healthy controls.

The optical device LIPOMETER enables the non-invasive, quick, and save determination of the thickness of subcutaneous adipose tissue layers at any given site of the human body. The specification of 15 evenly distributed body sites allows the precise measurement of subcutaneous body fat distribution, so-called subcutaneous adipose tissue topography (SAT-Top). In the present paper we focus on SAT...

متن کامل

Measurement and interpretation of subcutaneous fat, with norms for children and young adult males.

There is need for a simple and accurate measurement of surface body fat in view of the importance of this tissue from the nutritional and other points of view. Thus body fat, or its change, reflects the balance of an individual's energy intake and output, and this energy balance has been found to be the main determining factor in nutritional adequacy-at least in European countries (Berry, 1951)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2015