چکیده

BACKGROUND Vitamin E (VE) bonded polysulfone dialysis membranes have putative erythropoiesis stimulating agent (ESA)-sparing and anti-inflammatory properties based on data from a small number of studies. We sought to investigate this in a large, prospective 12-month randomized controlled trial. METHODS Two-hundred and sixty prevalent haemodialysis (HD) patients were randomized to dialysis with VE-bonded polysulfone membranes or non-VE-bonded equivalents. All ESA-dosing was performed by means of a computer-based anaemia management decision support system. Monthly data were used to calculate the ESA resistance index (ERI) and blood tests were performed at baseline, 6 and 12 months for measurement of C-reactive protein (CRP) levels. RESULTS Of the 260 patients, 123 were randomized to dialysis with the VE-membrane and 12-month data was available for 220 patients. At the study population level, no beneficial effect of the VE membranes on the ERI or CRP levels was observed. Post hoc analyses indicated that there was a significant fall in ERI for patients with the highest baseline ESA resistance dialysed with the VE (9.28 [7.70-12.5] versus 7.70 [5.34-12.7] IU/week/kg/g/dL Hb, P = 0.01) but not the control membranes (9.45 [7.62-12.3] versus 8.14 [4.44-15.6] IU/week/kg/g/dL Hb, P = 0.41); this was not attributable to changes in CRP levels. CONCLUSIONS Wholesale switching of all chronic HD patients to dialysis with VE-bonded polysulfone membranes appears not to be associated with improvements in ESA-responsiveness or CRP. These membranes may have utility in patients with heightened ESA resistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized controlled open-label trial of vitamin E-bonded polysulfone dialyzer and erythropoiesis-stimulating agent response.

BACKGROUND AND OBJECTIVES A 1-year multicenter prospective randomized controlled study was conducted on the effects of vitamin E-bonded polysulfone dialyzers on erythropoiesis-stimulating agent response in hemodialysis patients. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Major inclusion criteria were use of high-flux polysulfone dialyzers with 50-70 ml/min β2-microglobulin clearance over 3...

متن کامل

Evaluation of the Impact of a New Synthetic Vitamin E-Bonded Membrane on the Hypo-Responsiveness to the Erythropoietin Therapy in Hemodialysis Patients: A Multicenter Study.

BACKGROUND Oxidative stress has been related to hypo-response to erythropoiesis-stimulating agents (ESAs) in hemodialysis (HD) patients. The aim of this study was to verify whether vitamin E (ViE) on a synthetic polysulfone dialyzer can improve ESA responsiveness. METHODS This controlled, multicenter study involved 93 HD patients on stable ESA therapy, who were randomized to either ViE-coated...

متن کامل

It's time to compare anemia management strategies in hemodialysis.

Randomized trials of intravenous (IV) iron have repeatedly demonstrated a rise in hemoglobin (Hgb), an erythropoiesis-stimulating agent (ESA) dose-sparing effect, and apparent safety. Such benefits were confirmed in a trial in hemodialysis patients with high ferritin receiving high ESA doses. But long-term randomized safety trials of IV iron have not been performed, which critics blame on IV ir...

متن کامل

Long-term use of vitamin E-coated polysulfone membrane reduces oxidative stress markers in haemodialysis patients.

BACKGROUND Asymmetric dimethylarginine (ADMA) is an endogenous inhibitor of nitric oxide synthase and an independent predictor of overall mortality and cardiovascular outcome in haemodialysis (HD) patients. In the present study, we compared the effects of a vitamin E-coated polysulfone membrane (PSE) and a non-vitamin E-coated polysulfone membrane (PS) on oxidative stress markers such as ADMA. ...

متن کامل

Vitamin E-Coated Polysulfone Membrane-Based Hemodiafiltration Attenuates Inflammation in a Rat Model of Lipopolysaccharide-Induced Systemic Inflammation

Background: Acute blood purification (ABP) therapy is used regularly in the clinical setting and reportedly alleviates organ failure associated with severe systemic inflammatory responses, leading to reduced mortality. The present study aimed to determine whether there is a difference in efficacy between polysulfone (PS) membranes, which are currently used regularly in the clinical setting, and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2014