Three-year outcomes associated with embolic protection in saphenous vein graft intervention: results in 49 325 senior patients in the Medicare-linked National Cardiovascular Data Registry CathPCI Registry.
نویسندگان
چکیده
BACKGROUND Information is limited on contemporary use and outcomes of embolic protection devices (EPDs) in saphenous vein graft interventions. METHODS AND RESULTS We formed a longitudinal cohort (2005-2009; n=49 325) by linking National Cardiovascular Data Registry CathPCI Registry to Medicare claims to examine the association between EPD use and both procedural and long-term outcomes among seniors (65+ years), adjusting for clinical factors using propensity and instrumental variable methodologies. Prespecified high-risk subgroups included acute coronary syndrome and de novo or graft body lesions. EPDs were used in 21.2% of saphenous vein grafts (median age, 75; 23% women) and were more common in acute coronary syndrome (versus non-acute coronary syndrome; 22% versus 19%), de novo (versus restenotic; 22% versus 14%), and graft body lesions (versus aortic and distal anastomosis; 24% versus 20% versus 8%, respectively). EPDs were associated with a slightly higher incidence of procedural complications, including no reflow (3.9% versus 2.8%; P<0.001), vessel dissection (1.3% versus 1.1%; P=0.05), perforation (0.7% versus 0.4%; P=0.001), and periprocedural myocardial infarction (2.8% versus 1.8%; P<0.001). By 3 years, death, myocardial infarction, and repeat revascularization occurred in 25%, 15%, and 30% of cases, respectively. EPD use was associated with a similar adjusted risk of death (propensity score-matched hazard ratio, 0.96; 95% confidence interval, 0.91-1.02), myocardial infarction (propensity score-matched hazard ratio, 1.00; 95% confidence interval, 0.93-1.09), and repeat revascularization (propensity score-matched hazard ratio, 1.02; 95% confidence interval, 0.96-1.08) in the overall cohort and high-risk subgroups. CONCLUSIONS In this contemporary cohort, EPDs were used more commonly among patients with high-risk clinical indications, yet there was no evidence of improved acute- or long-term outcomes. Further prospective studies are needed to support routine EPD use.
منابع مشابه
Outcomes of Saphenous Vein Graft Intervention With and Without Embolic Protection Device: A Comprehensive Review and Meta-Analysis.
BACKGROUND Current guidelines give a class I recommendation to use of embolic protection devices (EPD) for saphenous vein graft (SVG) intervention; however, studies have shown conflicting results. The objective of this meta-analysis is to compare all-cause mortality, major adverse cardiovascular events, myocardial infarction (MI), or target vessel revascularization in SVG intervention with and ...
متن کاملLinking the National Cardiovascular Data Registry CathPCI Registry with Medicare claims data: validation of a longitudinal cohort of elderly patients undergoing cardiac catheterization.
BACKGROUND The National Cardiovascular Data Registry CathPCI Registry was recently linked with longitudinal Centers for Medicare & Medicaid (CMS) claims data. The degree to which this linked cohort is representative of the overall CathPCI Registry and CMS PCI populations is unknown. METHODS AND RESULTS CathPCI Registry records were linked to CMS inpatient claims using indirect identifiers. We...
متن کاملHospital Performance on Percutaneous Coronary Intervention Process and Outcomes Measures
BACKGROUND The Physician Consortium for Performance Improvement recently proposed percutaneous coronary intervention (PCI)-specific process measures. However, information about hospital performance on these measures and the association of PCI process and outcomes measures are not available. METHODS AND RESULTS We linked the National Cardiovascular Data Registry (NCDR) CathPCI Registry with Me...
متن کاملPatterns of stress testing and diagnostic catheterization after coronary stenting in 250 350 medicare beneficiaries.
BACKGROUND Patterns of noninvasive stress test (ST) and invasive coronary angiography (CA) utilization after percutaneous coronary intervention (PCI) are not well described in older populations. METHODS AND RESULTS We linked National Cardiovascular Data Registry CathPCI Registry data with longitudinal Medicare claims data for 250 350 patients undergoing PCI from 2005 to 2007 and described sub...
متن کاملEffect of race and ethnicity on outcomes with drug-eluting and bare metal stents: results in 423 965 patients in the linked National Cardiovascular Data Registry and centers for Medicare & Medicaid services payer databases.
BACKGROUND Black, Hispanic, and Asian patients have been underrepresented in percutaneous coronary intervention clinical trials; therefore, there are limited data available on outcomes for these race/ethnicity groups. METHODS AND RESULTS We examined outcomes in 423 965 patients in the National Cardiovascular Data Registry CathPCI Registry database linked to Medicare claims for follow-up. With...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2015