Left ventricular mass index measured by quantitative gated myocardial SPECT with 99mTc-tetrofosmin: a comparison with echocardiography.

نویسندگان

  • Kaoru Maruyama
  • Shinji Hasegawa
  • Daisaku Nakatani
  • Asit Kr Paul
  • Hideo Kusuoka
  • Tsunehiko Nishimura
  • Masatsugu Hori
  • Jun Hatazawa
چکیده

OBJECTIVE Left ventricular mass is an important determinant of diagnosis and prognosis in patients with heart disease. The aim of the present study was to validate measurement of the left ventricular mass index (LVMI) by quantitative gated myocardial SPECT (QGS) with 99mTc-tetrofosmin by comparing it with echocardiography. METHODS QGS and M-mode echocardiography (Echo) were performed within one month of each other in 179 patients. M-mode echocardiography was carried out according to Devereux's method. QGS images were acquired one hour after injection of 99Tc-tetrofosmin at rest. Myocardial volume was defined as the volume between the endocardial and epicardial surface in the end-diastolic phase. LVMI (g/m2) was defined as myocardial volume divided by myocardial specific density and corrected for body surface area. QGS LVMI measurements were performed twice by the same observer and independently by two different observers. Regional hypoperfusion in the group of patients with old myocardial infarction (n = 26) was evaluated semiquantitatively on the basis of the total defect score on the resting 99mTc-tetrofosmin SPECT images. RESULTS Among the patients as a whole QGS LVMI was significantly correlated with Echo LVMI (r = 0.96, p < 0.001). Intra-observer and inter-observer analyses showed significant reproducibility (r = 0.99 and r = 0.98, respectively, p < 0.001). In the patients with old myocardial infarction, but QGS LVMI was significantly lower than Echo LVMI (p < 0.001), and the magnitude of the underestimation was closely related to the severity of the perfusion defect on the resting SPECT images. CONCLUSIONS Measurements of LVMI by 99mTc-tetrofosmin QGS are reproducible and consistent with echocardiograpic estimates. Underestimation in patients with severe perfusion defects must be taken into consideration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

BACKGROUND Whether left ventricular function can be assessed accurately by gated single photon emission computed tomography (SPECT) in patients with myocardial infarction and severe perfusion defects is not well known. METHODS AND RESULTS Twenty-five patients with an acute myocardial infarction underwent 99mTc-labeled tetrofosmin (99mTc-tetrofosmin) gated SPECT and cine magnetic resonance ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2003