Magnetization transfer effects on T1-weighted three-dimensional gradient-echo MR images of a phantom simulating enhancing brain lesions.

نویسنده

  • D A Finelli
چکیده

PURPOSE To develop a simple tissue phantom to study the effects of various imaging parameters and gadolinium concentrations on magnetization transfer (MT) and lesion-to-background ratios. METHODS A commercial egg product was doped with gadolinium in concentrations of 0.0 to 1.0 mmol/L and cooked. The T1 and T2 values were determined for the phantom materials and for the white and gray matter of a healthy volunteer subject. The gadolinium-doped egg phantom and human brain were studied using a short-repetition-time three-dimensional gradient-echo MT sequence with various effective MT powers, frequency offsets, and section-select flip angles. The normalized signal intensities, MT ratios (MTRs), and simulated lesion-to-background normal white matter contrast ratios were determined for a variety of experimental conditions. RESULTS The MTR and lesion-to-background contrast ratios for all materials were greatest at the highest effective MT power (270 Hz, root-mean-square of amplitude) and the narrowest MT pulse frequency offset (1000 Hz). There was an inverse relationship between gadolinium concentration and MTR, and a positive relationship between the gadolinium concentration and lesion-to-background contrast. MTR was greatest at low flip angles, where there was little T1 weighting. The simulated lesion-to-background contrast showed a complex, gadolinium concentration-dependent relationship with section excitation flip angle. CONCLUSIONS The tissue phantom has relaxation properties and MT behavior close to that expected for enhancing brain lesions, allowing a rigorous analysis of simulated lesion-to-background contrast for high MT power, short-repetition-time, three-dimensional gradient-echo sequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.

PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...

متن کامل

Three-dimensional, T1-weighted gradient-echo imaging of the brain with a volumetric interpolated examination.

BACKGROUND AND PURPOSE T1-weighted, 3D gradient-echo MR sequences can be optimized for rapid acquisition and improved resolution through asymmetric k-space sampling and interpolation. We compared a volumetric interpolated brain examination (VIBE) sequence with a magnetization-prepared rapid acquisition gradient echo (MP RAGE) sequence and a 2D T1-weighted spin-echo (SE) sequence. METHODS Thir...

متن کامل

Enhanced and unenhanced MR with magnetization transfer in multiple sclerosis.

PURPOSE To evaluate the use of magnetization transfer and the apparent enhancement of lesions on contrast-enhanced MR images in patients with multiple sclerosis. METHODS Contrast-enhanced T1-weighted spin-echo MR images obtained in 20 patients with relapsing-remitting multiple sclerosis, with and without magnetization transfer, were evaluated to determine the number of enhancing plaques. Comp...

متن کامل

MR enhancement of brain lesions: increased contrast dose compared with magnetization transfer.

PURPOSE To compare image contrast and lesion conspicuity of enhancing intracranial lesions obtained with T1-weighted and magnetization transfer T1-weighted spin-echo sequences after administration of standard (0.1 mmol/kg body weight) and triple doses of gadobutrol. METHODS Twenty-four patients with a total of 34 enhancing intracranial lesions were studied with T1-weighted and magnetization t...

متن کامل

Magnetization transfer effects in MR-detected multiple sclerosis lesions: comparison with gadolinium-enhanced spin-echo images and nonenhanced T1-weighted images.

PURPOSE To define the relationship between magnetization transfer and blood-brain-barrier breakdown in multiple sclerosis lesions using gadolinium enhancement as an index of the latter. METHODS Two hundred twenty lesions (high-signal abnormalities on T2-weighted images) in 35 multiple sclerosis patients were studied with gadolinium-enhanced spin-echo imaging and magnetization transfer. Lesion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 1997