Effects of interfractional anatomical changes on water-equivalent pathlength in charged-particle radiotherapy of lung cancer.

نویسندگان

  • Shinichiro Mori
  • Hsiao-Ming Lu
  • John A Wolfgang
  • Noah C Choi
  • George T Y Chen
چکیده

Intrafractional motion and interfractional changes affect the accuracy of the delivered dose in radiotherapy, particularly in charged-particle radiotherapy. Most recent studies are focused on intrafractional motion (respiratory motion). Here, we report a quantitative simulation analysis of the effects of interfractional changes on water-equivalent pathlength (WEL) in charged-particle lung therapy. Serial four-dimensional (4D) CT scans were performed under free breathing conditions; the time span between the first and second 4DCT scans was five weeks. We quantified WEL changes between the first and second CT scans due to interfractional changes (tumor shrinkage and tissue density changes) and compared the particle-beam-stopping point between the serial 4DCT scans with use of the same initial bolus. Both tumor-shrinkage and lung-density changes were observed in a single patient over the course of therapy. The lung density decreased by approximately 0.1 g/cm(3) between the first and second-CT scans, resulting in a 1.5 cm WEL changes. Tumor shrinkage resulted in approximately 3 cm WEL changes. If the same initial bolus and plan were used through the treatment course, an unexpected significant beam overshoot would occur by interfractional changes due to tumor shrinkage and lung density variation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A serial 4DCT study to quantify range variations in charged particle radiotherapy of thoracic cancers

Weekly serial 4DCT scans were acquired under free breathing conditions to assess water-equivalent path length (WEL) variations due to both intrafractional and interfractional changes in tissue thickness and density and to calculate proton dose distributions resulting from anatomical variations observed in serial 4DCT. A template of region of interests (ROIs) was defined on the anterior-posterio...

متن کامل

The biological effects induced by high-charged and energy particles and its application in cancer therapy

The radiobiological effects of high atomic number and energy (HZE particles) ion beams are of interest for radioprotection in space and tumor radiotherapy. Space radiation mainly consists of heavy charged particles from protons to iron ions, which is distinct from common terrestrial forms of radiation. HZE particles pose a significant cancer risk to astronauts on prolonged space missions. With ...

متن کامل

Effects of anatomical changes on pencil beam scanning proton plans in locally advanced NSCLC patients.

BACKGROUND AND PURPOSE Daily anatomical variations can cause considerable differences between delivered and planned dose. This study simulates and evaluates these effects in spot-scanning proton therapy for lung cancer patients. MATERIALS AND METHODS Robust intensity modulated treatment plans were designed on the mid-position CT scan for sixteen locally advanced lung cancer patients. To estim...

متن کامل

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Evaluation of Lung Density and Its Dosimetric Impact on Lung Cancer Radiotherapy: A Simulation Study

Background: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations.Objective: The present study has been undertaken to find out inter- and intra- lung density variations and its dosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 50 6  شماره 

صفحات  -

تاریخ انتشار 2009