A tableted enzymic reagent for salicylate, for use in a discrete multiwavelength analytical system (Paramax).
نویسندگان
چکیده
A fully enzymic reagent for determination of salicylate in serum has been developed for use in the Paramax analytical system. The assay, run as an equilibrium determination, is based on the reaction of salicylate with NADPH and oxygen in the presence of salicylate hydroxylase (EC 1.14.13.1) to form catechol, NADP+, carbon dioxide, and water. The reaction is complete within 7 min, after which time the resulting absorbance change at 340/405 nm is measured. The sample:reagent ratio is 1:60 (5 microL of sample in a 300 microL final reaction volume). A single 30-mg tablet contains all of the reactants with tableting excipients. The use of NADPH eliminates interferences from reactions involving NADH. The large sample:reagent ratio, high sensitivity, and choice of bichromatic wavelengths minimize sample error. Results are linearly related to salicylate concentration to 1500 mg/L. Precision (CV) is 1.7% at 540 mg/L and 2.4% at 280 mg/L.
منابع مشابه
Discrete automated chemistry system with tableted reagents.
An instrument/reagent system with tableted reagents has been developed for performing ultraviolet/visible photometric assays. Preformed disposable plastic cuvettes pass through a stationary track every 5 s, providing a maximum throughput of 698 tests/h. The photometric system consists of a single light source with a separate set of light guides for each of eight photometer stations; bichromatic...
متن کاملSORtS FERRITIN (US/LI
The essential instrument settings are shown in Table 1. ‘Enzyme reagent was loaded as “2nd reagent,” and the modified color reagents A and B were “4th reagent” and “3rd reagent,” respectively. The instrument incubated sample and enzyme reagent for 4 mm in the inner chamber of the rotor. It then added 4-aminophenol to the inner chamber and sodium hydroxide to the outer chamber, mixed the content...
متن کاملInfluence of incomplete cholesteryl ester hydrolysis on enzymic measurements of cholesterol.
Esterolytic activity of three enzymic cholesterol reagents was evaluated with use of human serum-based reference materials. Primary cholesterol standards were used to calibrate the enzymic methods, and incomplete cholesteryl ester hydrolysis was measured as the bias between the enzymic cholesterol values and corresponding reference values. The average biases observed with eight reference specim...
متن کاملThe Lifetime Behavior of a New Discrete Time Mixed $delta$-shock Model
In this study, a mixed $delta$-shock model with discrete-time is defined by combining $delta$-shock and extreme shock models. In this model, a system with multiple states fails in two ways: first, when k interarrival times between two consecutive shocks with magnitude larger than the critical threshold $gamma$ are in $[delta_1, delta _2], delta_1 < delta _2$; and second, when the interarrival t...
متن کاملUse of Fenton Reagent as Advanced Oxidative Process for Removal of Basic and Acid Red Dyes from Aqueous Solutions
In this study, the Fenton process was used to investigate the color removal efficiency of Acid Red 52 and Basic Red 18 dye solutions by direct chemical oxidation. Color and chemical oxygen demand (COD) was successfully removed more than 99% and up to 92% respectively. This article would provide an easy assessment of the viability of using Fenton reagent in acidic conditions, so it is a prom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 8 شماره
صفحات -
تاریخ انتشار 1984