Maximum oxygen uptake utilising different treadmill protocols.
نویسندگان
چکیده
The study compared five treadmill protocols (four utilising a motorised, and one a non-motorised, treadmill) on maximum oxygen uptake. The five male and five female subjects, all actively engaged in training, were assigned the tests in random order. Statistical analysis revealed no significant differences between the five protocols for maximal oxygen uptake, maximum ventilation, maximum heart rate and blood lactate inflection point, relative to maximal oxygen uptake. Significant differences were observed between the 3' protocol with incline increments of 1.5% and all other protocols on time to exhaustion (p = less than 0.01) and maximum blood lactate levels (HLA, p = less than 0.05). The results indicate that the protocols used in this study did not significantly influence the maximum oxygen uptake attained.
منابع مشابه
Comparison of the ramp versus standard exercise protocols.
To compare the hemodynamic and gas exchange responses of ramp treadmill and cycle ergometer tests with standard exercise protocols used clinically, 10 patients with chronic heart failure, 10 with coronary artery disease who were asymptomatic during exercise, 11 with coronary artery disease who were limited by angina during exercise and 10 age-matched normal subjects performed maximal exercise u...
متن کاملTreadmill protocols for determination of maximum oxygen uptake in runners.
Four testing protocols were completed by each of 10 runners using a common speed for protocols 1 and 2 (P1 and P2), each runner's training pace for protocol 3 (P3) and a speed selected manually by the runner for protocol 4 (P4). Stages were increased by 2.5% grade every 2 min for each protocol except for P1, which had 1 min stages. There were no significant differences in maximum oxygen uptake ...
متن کاملModeling Oxygen Uptake during V1 Treadmill Roller Skiing
The use of regression equations to predict oxygen uptake in relation to speed, grade, power output, and anthropometric characteristics is common in cardiac rehabilitation and athlete fitness testing. Research has suggested that sport specific testing improves the reliability of the test methodology and is appropriate for the development of effective training programs. This study focused on the ...
متن کاملهمبستگی آزمونهای تردمیل (Gerkin) و پله (ACSM) در برآورد حداکثر ظرفیت هوازی (VO2-max)
Background and aims: The maximum aerobic capacity or VO2max is a measure of the maximum volume of oxygen that can be absorbed by respiratory system and delivered to the acting muscles through blood flow. The aims of this study were to determine the correlation between the two methods of treadmill and step tests in estimating the maximum aerobic capacity and it's affecting factors among students...
متن کاملEvaluation of a new treadmill exercise protocol.
STUDY OBJECTIVES To confirm that a newly drafted treadmill exercise protocol designed on a theoretical basis to span a range of 0 to 200 W with approximately 25-W increments by alteration of either speed or grade from one stage to the next should correspond to a standard bicycle protocol consisting of 25-W steps. DESIGN Randomized, crossover study to compare both exercise test modes. STUDY ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of sports medicine
دوره 18 2 شماره
صفحات -
تاریخ انتشار 1984