OBJECTIVES The aim of this study was to examine the effect of basic fibroblast growth factor (FGF-2) on osseointegration of dental implants with low primary stability in a beagle dog model. MATERIALS AND METHODS Customized titanium implants that were designed to have low contact with the existing bone were installed into the edentulous mandible of beagle dogs. To degrade the primary stability of the implants, the diameters of the bone sockets exceeded the implant diameters. FGF-2 (0.3%) plus vehicle (hydroxypropyl cellulose) or vehicle alone was topically applied to the sockets in the FGF-2 and control groups, respectively. In Study 1, the new bone area and length of new bone-to-implant contact (BIC) were evaluated at 4, 8, and 12 weeks after installation using histomorphometry and scanning electron microscopy. In Study 2, the implant stability quotient (ISQ) values were sequentially measured for 16 weeks using an Osstell system. RESULTS The histomorphometric analysis revealed that the new bone area and length of BIC in the FGF-2 group were significantly larger than those in the control group at 4 weeks. Electron microscopic observation showed intimate contact between the mature lamellar bone and the implant surfaces, osseointegration, in both groups. The ISQ values in the FGF-2 group were significantly increased from 6 to 16 weeks compared with those in the control group. CONCLUSIONS Taken together, our study demonstrates that FGF-2 promoted new bone formation around the dental implants and subsequent osseointegration, resulting in promotion of stability of implants with low primary stability.
منابع مشابه
The Influence of Site Preparation (Countersinking) on Initial Dental Implant Stability. An in vitro Study Using Resonance Frequency Analysis
Primary implant stability is considered to be a critical factor for obtaining successful osseointegration [1]. Studies using Resonance Frequency Analysis (RFA) have demonstrated that initial implant stability is determined by the density of the bone, the surgical technique used, and the design of the implant [2, 3]. While different implant designs have shown similar results of higher stabilitie...
متن کاملImplant stability change and osseointegration speed of immediately loaded photofunctionalized implants.
OBJECTIVES This study evaluated the degree and rate of implant stability development for photofunctionalized dental implants in humans. MATERIALS AND METHODS Thirty-three implants (7 patients) placed in the maxilla and immediate loaded were evaluated. Photofunctionalization was performed by treating implants with ultraviolet for 15 minutes immediately before placement. Implant stability was a...
متن کاملDental Implant Design and Biological Effects on Bone-Implant Interface
Although dental implants have become a predictable aspect of tooth replacement in prosthodontic treatment [1, 2, 3, 4, 5, 6], failures of up to 10% are still encountered. Furthermore these failures have been more associated with “soft” bone quality [7], 1985) such as encountered in the maxillary posterior area [8, 9, 10, 11, 12]. In a review article by Esposito et al [13], bone quality and volu...
متن کاملImplant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.
Osseointegrated implants for prosthetic rehabilitation of the edentulous patient show high success rates if certain preconditions are fulfilled. Implant stability plays a critical role for a successful critical outcome since short implants and implants placed in soft bone are more prone to failure (13, 49). In the original protocols for implant placement, primary implant stability was ensured b...
متن کاملIn vitro analysis of the influence of surface treatment of dental implants on primary stability.
Surface treatment interferes with the primary stability of dental implants because it promotes a chemical and micromorphological change on the surface and thus stimulates osseointegration. This study aimed to evaluate the effects of different surface treatments on primary stability by analyzing insertion torque (IT) and pullout force (PF). Eight samples of implants with different surface treatm...