A Compton-Suppressed Phoswich Detector for Gamma Spectroscopy

نویسنده

  • A. T. Farsoni
چکیده

A phoswich detector with two scintillation layers has been designed and assembled at Oregon State University. This detector is able to identify and reject Compton events and ultimately reduce the Compton continuum in gamma energy spectra. In this detector, CsI(Tl) crystal is used to primarily detect photoelectric events. The CsI(Tl) crystal is partially surrounded by a BGO crystal layer to capture and identify Compton-scattered photons. Both crystals are optically coupled to a single photomultiplier tube. A real-time, FPGA-based digital pulse shape analysis was developed to discriminate and reject Compton-induced pulses from the CsI(Tl) crystal. All the digital pulse processing functions including pulse shape discrimination analysis, pile-up rejection and energy measurement were implemented in an on-board FPGA device. In this paper, the results of recent measurements using radioactive lab sources will be presented and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Modeling of a Compton-suppressed Phoswich Detector for Radioxenon Monitoring

By measuring the concentration of four xenon radioisotopes in the atmosphere, the International Monitoring System (IMS) can verify nuclear weapons tests around the world. To measure ultra-low concentrations of radioxenons, many detection systems, such as the Automated Radioxenon Sampler and Analyzer (ARSA) and the Swedish Automatic Unit for Noble gas Acquisition (SAUNA), have been developed and...

متن کامل

Beam test of a prototype phoswich detector assembly for the PoGOLite astronomical soft gamma-ray polarimeter

We report about the beam test on a prototype of the balloon-based astronomical soft gamma-ray polarimeter, PoGOLite (Polarized Gamma-ray Observer Light Version) conducted at KEK Photon Factory, a synchrotron radiation facility in Japan. The synchrotron beam was set at 30, 50, and 70 keV and its polarization was monitored by a calibrated polarimeter. The goal of the experiment was to validate th...

متن کامل

Real-Time Pulse-Shape Discrimination and Beta-Gamma Coincidence Detection in Field- Programmable Gate Array

A real-time FPGA-based algorithm has been developed and tested to discriminate pulse-shapes, identify beta-gamma coincidence events and collect energy spectra from xenon radioisotopes using a phoswich detector. The detector consists of a thin plastic scintillator (BC-400) to detect beta and conversion electrons, a CsI(Tl) crystal for measuring X-rays and gamma-rays, and a BGO crystal, which sur...

متن کامل

Preliminary Experiments with a Triple-layer Phoswich Detector for Radioxenon Detection

The International Monitoring System (IMS) employs some special radiation detectors to monitor atmospheric or underground nuclear weapons tests around the world. These detectors should be able to detect ultra low concentrations of xenon radioisotopes in the atmosphere where the background level is relatively high. Exploiting the fact that the most interesting xenon radioisotopes (Xe, Xe, Xe, and...

متن کامل

Characterizing a Two-channel Phoswich Detector Using Radioxenon Isotopes Produced in the Oregon State University Triga Reactor

Low concentrations of radioxenon isotopes can be measured with a high sensitivity using beta/gamma coincidence technique. In this technique, a coincidence event is recorded when two signals from beta and gamma detection channels are detected simultaneously. These two coincident signals are then processed to establish a two-dimensional beta/gamma coincidence spectrum in which the four radioxenon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013