Analysis By Time-Of-Flight Secondary Ion Mass Spectroscopy or Nuclear Products In Hydrogen Penetration Through Palladium

نویسنده

  • H. YAMADA
چکیده

Elemental analysis was performed for the palladium foil through which the hydrogen gas penetrated. We analyzed sample surface by Time-of-Flight secondary ion mass spectroscopy and searched for newly produced elements during the gas permeation process. Significant increase of the counts for Cr, Fe, Cu and Ag were found after the permeation. These elements could have been produced by nuclear transmutation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimum Heat of Formation of Potassium Iodo Hydride

] that a novel inorganic hydride compound KHI which comprised a high binding energy hydride ion was synthesized by reaction of atomic hydrogen with potassium metal and potassium iodide. Potassium iodo hydride was identified by time of flight secondary ion mass spectroscopy, X-ray photoelectron spectroscopy, 1 H and 39 K nuclear magnetic resonance spectroscopy, Fourier transform infrared spectro...

متن کامل

Gamma Ray Detection and Surface Analysis on Palladium Electrode in DC Glow-like Discharge Experiment

We performed glow-like discharge experiments using deuterated palladium cathode in deuterium atmosphere to investigate the possibility of inducing low-energy nuclear reaction. Anomalous gamma ray emissions in the 80 230keV region were sometimes observed. It was assumed that a nuclear reaction took place during the experiment, producing short-lived radioisotopes, and these radioisotopes emitted ...

متن کامل

Experimental Observation of the New Elements Production in the Deuterated And/or Hydride Palladium Electrodes, Exposed to the Low Energy Dc

Elemental and isotopic structures of the palladium cathode before and after experiment under DC glow discharge were investigated by time of flight secondary ion mass spectrometry (TOF-SIMS). Production of new elements with various atomic masses and impurities increase were surveyed. By analyzing obtained results, it was found that beryllium and nickel for deuterium-palladium system, and lithium...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Tritium Production in Palladium Deuteride/hydride in Evacuated Chamber

The controlled out-diffusion method was employed to induce a nuclear reaction in a palladium (Pd) plate with a MnOx film. The time-resolved mass spectra for Pd deuteride revealed tritium (T) production during the outdiffusion experiment. Similar time behaviors of mass number 1-4 and 6 in the spectra was also observed for Pd hydride. Film blackening was observed for most Pd deuteride as well as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003