Is it safe to leave an ECMO circuit primed?
نویسندگان
چکیده
Extracorporeal membrane oxygenation (ECMO) is a means of life support for failing patients who require extreme life-saving measures due to failure of their heart, lungs or both organs. In a patient suffering cardiac arrest, the faster circulation via cardiopulmonary resuscitation (CPR) can be instituted the better the outcome is. If an ECMO circuit needs to be built and primed it may add significant minutes to the response time. The purpose of this study is to test for any growth in primed ECMO circuits at given time intervals to prove the safety of leaving an ECMO circuit primed. This, in turn, may lead to decreased response time, with an arrest and the placement of the arresting patient on ECMO. Five ECMO circuits were set up, primed and sampled for bacterial growth at 0, 24, 48 and 72 hours and then at one-week intervals, with an end point of four weeks. No bacterial growth was found at any point during the sampling process.
منابع مشابه
Propofol, midazolam, vancomycin and cyclosporine therapeutic drug monitoring in extracorporeal membrane oxygenation circuits primed with whole human blood
INTRODUCTION As a result of drug sequestration and increased volume of distribution, the extracorporeal membrane oxygenation (ECMO) procedure might lead to a decrease in drug concentrations during a patient's treatment. The aim of this study was to evaluate sedative, antibiotic and immunosuppressive drug loss in ECMO circuit using ex-vivo and in-vitro experiments. METHODS Blood concentrations...
متن کاملQuantification of perflutren microsphere contrast destruction during transit through an ex vivo extracorporeal membrane oxygenation circuit.
BACKGROUND Echocardiography is a key investigation in the management of patients on extracorporeal membrane oxygenation (ECMO). However, echocardiographic images are often non-diagnostic in this patient population. Contrast-enhanced echocardiography may overcome many of these limitations but contrast microspheres are hydrodynamically labile structures prone to destruction from shear forces and ...
متن کاملSequestration of drugs in the circuit may lead to therapeutic failure during extracorporeal membrane oxygenation
INTRODUCTION Extracorporeal membrane oxygenation (ECMO) is a supportive therapy, with its success dependent on effective drug therapy that reverses the pathology and/or normalizes physiology. However, the circuit that sustains life can also sequester life-saving drugs, thereby compromising the role of ECMO as a temporary support device. This ex vivo study was designed to determine the degree of...
متن کاملThe use of continuous renal replacement therapy in series with extracorporeal membrane oxygenation.
A large percentage of patients on extracorporeal membrane oxygenation (ECMO) require continuous renal replacement therapy (CRRT) usually performed through a different venous access or by introducing a filter into the ECMO circuit. Here, we evaluated the efficacy and safety of including a CRRT machine in the circuit by connecting its inlet line after the centrifugal pump and its outlet line befo...
متن کاملMacro- and micronutrient disposition in an ex vivo model of extracorporeal membrane oxygenation
BACKGROUND Extracorporeal membrane oxygenation (ECMO) circuits have been shown to sequester circulating blood compounds such as drugs based on their physicochemical properties. This study aimed to describe the disposition of macro- and micronutrients in simulated ECMO circuits. METHODS Following baseline sampling, known quantities of macro- and micronutrients were injected post oxygenator int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال: