Forced-air patient warming blankets disrupt unidirectional airflow.

نویسندگان

  • A J Legg
  • A J Hamer
چکیده

We have recently shown that waste heat from forced-air warming blankets can increase the temperature and concentration of airborne particles over the surgical site. The mechanism for the increased concentration of particles and their site of origin remained unclear. We therefore attempted to visualise the airflow in theatre over a simulated total knee replacement using neutral-buoyancy helium bubbles. Particles were created using a Rocket PS23 smoke machine positioned below the operating table, a potential area of contamination. The same theatre set-up, warming devices and controls were used as in our previous study. This demonstrated that waste heat from the poorly insulated forced-air warming blanket increased the air temperature on the surgical side of the drape by > 5°C. This created convection currents that rose against the downward unidirectional airflow, causing turbulence over the patient. The convection currents increased the particle concentration 1000-fold (2 174 000 particles/m(3) for forced-air warming vs 1000 particles/m(3) for radiant warming and 2000 particles/m(3) for the control) by drawing potentially contaminated particles from below the operating table into the surgical site. Cite this article: Bone Joint J 2013;95-B:407-10.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do forced air patient-warming devices disrupt unidirectional downward airflow?

Patient warming significantly decreases the risk of surgical site infection. Recently there have been concerns that forced air warming may interfere with unidirectional airflow, potentially posing an increased risk of infection. Our null hypothesis was that forced air and radiant warming devices do not increase the temperature and the number of particles over the surgical site when compared wit...

متن کامل

ARTHROPLASTY Do forced air patient - warming devices disrupt unidirectional downward airflow ?

J Bone Joint Surg Br 2012;94-B:254––6. Received 7 June 2011; Accepted after revision 14 September 2011 Patient warming significantly decreases the risk of surgical site infection. Recently there have been concerns that forced air warming may interfere with unidirectional airflow, potentially posing an increased risk of infection. Our null hypothesis was that forced air and radiant warming devic...

متن کامل

Forced-air warming and ultra-clean ventilation do not mix: an investigation of theatre ventilation, patient warming and joint replacement infection in orthopaedics.

We investigated the capacity of patient warming devices to disrupt the ultra-clean airflow system. We compared the effects of two patient warming technologies, forced-air and conductive fabric, on operating theatre ventilation during simulated hip replacement and lumbar spinal procedures using a mannequin as a patient. Infection data were reviewed to determine whether joint infection rates were...

متن کامل

Do warming blankets increase bacterial counts in the operating field in a laminar-flow theatre?

Patient warming systems are used routinely to prevent hypothermia under anaesthesia. Airflow from warming blankets may potentially influence bacterial counts either by pumping 'dirty air' from floor level to the operating area or by blowing the patients' skin cells into the operating field from airflow under the blanket. Using slit-air sampling we analysed the air quality within a laminar-flow ...

متن کامل

Meta-analysis: effectiveness of forced-air warming for prevention of perioperative hypothermia in surgical patients.

AIM The aim of this study was to evaluate the effectiveness of forced-air warming for preventing perioperative hypothermia. BACKGROUND Perioperative hypothermia commonly occurs in patients receiving anaesthesia during surgeries. However, the effectiveness of warming systems requires verification. DESIGN Systematic review incorporating meta-analysis. DATA SOURCES We searched OVID, PubMed, ...