Wound and surface temperatures in vivo in torsional and longitudinal modalities of ultrasound in coaxial microincisional cataract surgery

نویسندگان

  • Swapna Nair
  • Ramachandran Unnikrishnan Nair
چکیده

BACKGROUND To study phacoemulsification probe shaft/wound and corneal surface/tip temperatures in vivo during longitudinal, torsional and combined phacoemulsification modes and their relationship to machine parameters. DESIGN This was a prospective study at Chaithanya Eye Hospital and Research Institute, Trivandrum, India (tertiary). PARTICIPANTS Twenty-two eyes of 22 patients were randomized into six groups depending on the grade of nuclear sclerosis (NS) and the type of ultrasound used: Group 1, torsional in NS2; Group 2, torsional in NS3; Group 3, torsional with intermittent longitudinal in NS2; Group 4, torsional with intermittent longitudinal in NS3; Group 5, longitudinal in NS2; Group 6, longitudinal in NS3. METHODS Patients underwent phacoemulsification by torsional, longitudinal or combined modalities. A thermal camera was used to measure phaco probe temperatures. MAIN OUTCOME MEASURES The mean probe shaft and tip temperatures were documented for different ultrasound modalities. RESULTS The mean shaft and tip temperatures were: Group 1, 29.22°C±0.71°C and 28.4°C±0.88°C; Group 2, 32.12°C±0.62°C and 31.88°C±0.84°C; Group 3, 30.25°C±0.71°C and 29.35°C±0.62°C; Group 4, 31.95°C±0.65°C and 32.01°C±1.31°C; Group 5, 23°C and 27.6°C and Group 6, 23°C and 29.68°C, respectively. In all groups using longitudinal ultrasound, the phaco tip surface temperatures were higher than the shaft temperatures, except in Group 3. Shaft temperatures were higher than tip temperatures in cases using torsional phaco, except in Group 4. The mean temperature difference between groups was significant only for shaft temperatures (P=0.001). On thermal imaging, for torsional phaco, the rise in temperature of the probe from shaft to tip was dependent on the amplitude of ultrasound applied (P=0.009). CONCLUSION The shaft temperatures were higher than over the phaco tip during torsional phacoemulsification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TORSIONAL AND MICRO-COAXIAL TECHNOLOGY: New Efficiencies in Challenging Cases

I would like to present our experiences with torsional and micro-coaxial technology on behalf of our French research group. My goal is to demonstrate to surgeons the transition from performing phacoemulsification with traditional longitudinal ultrasound to a micro-coaxial procedure using torsional technology. The impetus for the development of micro-incisional phacoemulsification was to provide...

متن کامل

Fluid dynamics, cavitation, and tip-to-tissue interaction of longitudinal and torsional ultrasound modes during phacoemulsification.

PURPOSE To describe the fluidic events that occur in a test chamber during phacoemulsification with longitudinal and torsional ultrasound (US) modalities. SETTING Pasteur Ophthalmic Clinic Phacodynamics Laboratory, Santiago, Chile, and Nanyang Technological University, Singapore. DESIGN Experimental study. METHODS Ultra-high-speed videos of a phacoemulsifying tip were recorded while the t...

متن کامل

Today’s Practice Cataract Fundamentals

T oday, the aim of cataract surgery is not only to restore vision by removing and replacing the cataractous lens, but also to simultaneously provide instant and high-quality visual rehabilitation. Achieving a clear cornea immediately after surgery is the first step in this endeavor. One of the most important barriers to achieving clear corneas and sharp vision immediately after cataract surgery...

متن کامل

Cataract Surgery Focus on Phaco Technology

MARCH 2007 I CATARACT & REFRACTIVE SURGERY TODAY I 37 W ith its new Stellaris Vision Enhancement System (FDA approved, commercial launch in US planned for April 2007) (Figure 1), Bausch & Lomb (Rochester, NY) has designed an integrated phaco platform with advanced technology and precise instrumentation that will facilitate surgeons’ transition to the newer microincisional phaco techniques. The ...

متن کامل

تخمین غیرتهاجمی مدول الاستیک چشم کاتاراکته شده خرگوش

    Although cataract is very common and its detection seems apparently easy especially in the mature cataract, its quantitative description to determine the critical value of diagnosis is too difficult. Non-invasive evaluation of the mechanical properties of eye is hampered by the absence of in-vivo methods for direct assessment of the axial length of eye, lens and cornea. In the present study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017