Is there a gender difference in noninvasive coronary imaging? Multislice computed tomography for noninvasive detection of coronary stenoses

نویسندگان

  • Marc Dewey
  • Wolfgang Rutsch
  • Bernd Hamm
چکیده

BACKGROUND Multislice computed tomography (MSCT) coronary angiography is the foremost alternative to invasive coronary angiography. METHODS We sought to compare the diagnostic accuracy of MSCT in female and male patients with suspected coronary disease. Altogether 50 women and 95 men underwent MSCT with 0.5 mm detector collimation. Coronary artery stenoses of at least 50% on conventional coronary angiography were considered significant. RESULTS The coronary vessel diameters of all four main coronary artery branches were significantly larger in men than in women. The diagnostic accuracy of MSCT in identifying patients with coronary artery disease was significantly lower for women (72%) compared with men (89%, p < 0.05). Also sensitivity (70% vs. 95%), positive predictive value (64% vs. 93%), and the rate of nondiagnostic examinations (14% vs. 4%, all: p < 0.05) were significantly worse for women. The effective radiation dose of MSCT coronary angiography was significantly higher in the examination of women (13.7 +/- 1.2 mSv) than of men (11.7 +/- 0.9 mSv, p < 0.001), mainly as a result of the fact that the radiosensitive female breast (contributing 24.5% of the dose in women) is in the x-ray path. CONCLUSION Noninvasive coronary angiography with MSCT might be less accurate and sensitive for women than men. Also, women are exposed to a significantly higher effective radiation dose than men.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive evaluation of the coronary arteries with multislice computed tomography in hypertensive patients.

Because patients with hypertension are at increased risk for coronary artery disease, early and noninvasive identification of the disease in patients with hypertension is important. Recently, multislice computed tomography (MSCT) has been demonstrated to allow both noninvasive coronary angiography and assessment of left ventricular function. The purpose of the present study therefore was to dem...

متن کامل

Noninvasive coronary angiography with multislice computed tomography.

CONTEXT Multislice computed tomography (MSCT) has recently evolved as a modality for noninvasive coronary imaging. OBJECTIVE To assess the accuracy and robustness of MSCT vs the criterion standard of invasive coronary angiography for detection of obstructive coronary artery disease. DESIGN, SETTING, AND PATIENTS Prospective, single-center study conducted in a referral center setting in Germ...

متن کامل

Noninvasive angiography and assessment of left ventricular function using multislice computed tomography in patients with type 2 diabetes.

OBJECTIVE Early identification of coronary artery disease (CAD) in patients with diabetes is important because these patients are at increased risk for CAD and have worse outcome than nondiabetic patients after CAD is diagnosed. Recently, noninvasive coronary angiography and assessment of left ventricular function has been demonstrated with multislice computed tomography (MSCT). The purpose of ...

متن کامل

ارزش تشخیصی -MSCT آنژیوگرافی با تکنولوژی  64 - Sliceدر مقایسه با آنژیوگرافی مرسوم در شناسایی بیماری شریان کرونری

Background: Multislice computed tomography (MSCT) is a noninvasive method of detecting coronary artery disease (CAD). The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64-MSCT) in daily practice, without patient selection. Methods: Sixty-four consecutive suspected CAD patients underwent both 64-MSCT and quantitative coronary angiography (QCA). The CT system The...

متن کامل

CORONARY ANGIOGRAPHY Potential intrinsic error of noninvasive coronary angiography

Purpose. With current noninvasive techniques compromises have to be accepted for coronary imaging, e.g., partial coverage of the coronary artery tree. The aim of the study was to estimate the potential intrinsic error of partial coverage from a database of invasive angiograms. Methods and Results. The localization and severity of coronary artery stenoses and, if percutaneous coronary interventi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Cardiovascular Disorders

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008