Inferior colliculus responses to multichannel microstimulation of the ventral cochlear nucleus: implications for auditory brain stem implants.

نویسندگان

  • Mohit N Shivdasani
  • Stefan J Mauger
  • Graeme D Rathbone
  • Antonio G Paolini
چکیده

Multichannel techniques were used to assess the frequency specificity of activation in the central nucleus of the inferior colliculus (CIC) produced by electrical stimulation of localized regions within the ventral cochlear nucleus (VCN). Data were recorded in response to pure tones from 141 and 193 multiunit clusters in the rat VCN and the CIC, respectively. Of 141 VCN sites, 126 were individually stimulated while recording responses in the CIC. A variety of CIC response types were seen with an increase in both electrical and acoustic stimulation levels. The majority of sites exhibited monotonic rate-level types acoustically, whereas spike rate saturation was achieved predominantly with electrical stimulation. In 20.6% of the 364 characteristic frequency aligned VCN-CIC pairs, the CIC sites did not respond to stimulation. In 26% of the 193 CIC sites, a high correlation was observed between acoustic tuning and electrical tuning obtained through VCN stimulation. A high degree of frequency specificity was found in 58% of the 118 lowest threshold VCN-CIC pairs. This was dependent on electrode placement within the VCN because a higher degree of frequency specificity was achieved with stimulation of medial, central, and posterolateral VCN regions than more anterolateral regions. Broadness of acoustic tuning in the CIC played a role in frequency-specific activation. Narrowly tuned CIC sites showed the lowest degree of frequency specificity on stimulation of the anterolateral VCN regions. These data provide significant implications for auditory brain stem implant electrode placement, current localization, power requirements, and facilitation of information transfer to higher brain centers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Translational Physiology Inferior Colliculus Responses to Multichannel Microstimulation of the Ventral Cochlear Nucleus: Implications for Auditory Brain Stem Implants

Shivdasani MN, Mauger SJ, Rathbone GD, Paolini AG. Inferior colliculus responses to multichannel microstimulation of the ventral cochlear nucleus: implications for auditory brain stem implants. J Neurophysiol 99: 1–13, 2008. First published October 10, 2007; doi:10.1152/jn.00629.2007. Multichannel techniques were used to assess the frequency specificity of activation in the central nucleus of t...

متن کامل

Descending Connections of Auditory Cortex to theMidbrain and Brain Stem

AI primary auditory cortex AC auditory cortex BDA biotinylated dextran amines BF best frequency CNC cochlear nuclear complex CNIC central of the inferior colliculus DCN dorsal cochlear nucleus DCIC dorsal cortex of the inferior colliculus DNLL dorsal nucleus of the lateral lemniscus DSCF Doppler-shifted constant frequency ECIC external cortex of the inferior colliculus ES electrical stimulation...

متن کامل

Hannover Medical University Clinic of Laryngology, Rhinology and Otology / University of Veterinary Medicine Hannover Investigation of Novel Auditory Implants of the Inferior Colliculus

A1 Primary auditory cortex ABI Auditory brainstem implant AMI Auditory midbrain implant CI Cochlear implant DBS Deep brain stimulation IC Inferior colliculus ICC Inferior colliculus central nucleus LFP Local field potential MSS Multi-site stimulation MUA Multi unit analysis NP NeuroProbe PSTH Post stimulus time histogram SC Superior colliculus SSS Single site stimulation

متن کامل

An in vivo investigation of inferior colliculus single neuron responses to cochlear nucleus pulse train stimulation.

The auditory brain stem implant (ABI) is being used clinically to restore hearing to patients unable to benefit from a cochlear implant (CI). Speech perception outcomes for ABI users are typically poor compared with most CI users. The ABI is implanted either on the surface of or penetrating through the cochlear nucleus in the auditory brain stem and uses stimulation strategies developed for aud...

متن کامل

Enhancement of forward suppression begins in the ventral cochlear nucleus

A neuron׳s response to a sound can be suppressed by the presentation of a preceding sound. It has been suggested that this suppression is a direct correlate of the psychophysical phenomenon of forward masking, however, forward suppression, as measured in the responses of the auditory nerve, was insufficient to account for behavioural performance. In contrast the neural suppression seen in the i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 99 1  شماره 

صفحات  -

تاریخ انتشار 2008