Speckle-tracking echocardiography correctly identifies segmental left ventricular dysfunction induced by scarring in a rat model of myocardial infarction.

نویسندگان

  • Zoran B Popović
  • Carlos Benejam
  • Jing Bian
  • Niladri Mal
  • Jeannie Drinko
  • Kwangdeok Lee
  • Farhad Forudi
  • Rachel Reeg
  • Neil L Greenberg
  • James D Thomas
  • Marc S Penn
چکیده

Speckle-tracking echocardiography (STE) uses a two-dimensional echocardiographic image to estimate two orthogonal strain components. The aim of this study was to assess sensitivity of circumferential (S(circ)) and radial (S(rad)) strains to infarct-induced left ventricular (LV) remodeling and scarring of the LV in a rat. To assess the relationship among S(circ), S(rad), and scar size, two-dimensional echocardiographic LV short-axis images (12 MHz transducer, Vivid 7 echo machine) were collected in 34 Lewis rats 4 to 10 wk after ligation of the left anterior descending artery. Percent segmental fibrosis was assessed from histological LV cross sections stained by Masson trichrome. Ten normal rats served as echocardiographic controls. S(circ) and S(rad) were assessed by STE. Histological data showed consistent scarring of anterior and lateral segments with variable extension to posterior and inferior segments. Both S(circ) and S(rad) significantly decreased after myocardial infarction (P<0.0001 for both). As anticipated, S(circ) and S(rad) were lowest in the infarcted segments. Multiple linear regression showed that segmental S(circ) were similarly dependent on segmental fibrosis and end-systolic diameter (P<0.0001 for both), whereas segmental S(rad) measurements were more dependent on end-systolic diameter (P<0.0001) than on percent fibrosis (P<0.002). STE correctly identifies segmental LV dysfunction induced by scarring that follows myocardial infarction in rats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Echocardiographic assessment of myocardial infarction: comparison of a rat model in two strains

The purpose of this study was to induce myocardial infarction (MI) and compare the echocardiographic parameters and mortality ratio of Lewis inbred and Wistar outbred strain before and after the procedure to help choose the best one for MI studies. In this study MI was induced in 46 Lewis and 34 Wistar by occlusion of left anterior descending artery (LAD). Doppler, two-dimensional (2-D) and 2-D...

متن کامل

Assessment of Subclinical Myocardial Changes in Non-Alcoholic Fatty Liver Disease: A Case-Control Study Using Speckle Tracking Echocardiography

Background: Considering the association between cardiac abnormalities and non-alcoholic fatty liver disease (NAFLD), the present study aimed to evaluate the relationship between biopsy-proven NAFLD and functional echocardiographic parameters, including left ventricular (LV) global longitudinal strain (GLS) in asymptomatic individuals. Methods: Thirty asymptomatic patients with liver biopsy-prov...

متن کامل

Assessment of left ventricular regional function in affected and carrier dogs with duchenne muscular dystrophy using speckle tracking echocardiography

BACKGROUND Two-dimensional speckle tracking echocardiography (STE) is a relatively new method to detect regional myocardial dysfunction. To assess left ventricular (LV) regional myocardial dysfunction using STE in Duchenne muscular dystrophy model dogs (CXMD(J)) without overt clinical signs of heart failure. METHODS Six affected dogs, 8 carrier dogs with CXMD(J), and 8 control dogs were used....

متن کامل

Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI). The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 292 6  شماره 

صفحات  -

تاریخ انتشار 2007