Three-dimensional motions of distal syndesmosis during walking.

نویسندگان

  • Chen Wang
  • Junsheng Yang
  • Shaobai Wang
  • Xin Ma
  • Xu Wang
  • Jiazhang Huang
  • Chao Zhang
  • Li Chen
  • Jian Xu
  • Xiang Geng
  • Kan Wang
چکیده

INTRODUCTION The motion of the distal syndesmosis correlates highly with the instability, while an accurate kinematic description of the distal tibiofibular joint during normal gait has not previously been presented. MATERIAL AND METHODS Sixteen healthy syndesmoses of sixteen living subjects (8 male and 8 female) were studied during stance phase of the normal gait. Data of CT scanning were collected first and used to create the 3D models of the distal tibia and fibula. The lateral X-ray images of the syndesmosis were captured by fluoroscopy when the subject was walking. Seven key-pose images were selected for subsequent 3D to 2D bone model registration and six degrees-of-freedom (DOF) motions of syndesmosis were then calculated. A validation experiment was also conducted to confirm the accuracy of the 3D/2D technique for the syndesmosis. RESULTS During the stance phase, the distal tibiofibular joint exhibited with 2.98 ± 1.10° of dorsi/plantarflexion, 5.94 ± 1.52° of inversion/eversion, and 5.99 ± 2.00° of internal/external rotation; 2.63 ± 1.05 mm on medial/lateral, 3.86 ± 1.65 mm on anterior/posterior, and 4.12 ± 1.53 mm on superior/inferior translation. From heel strike to mid-stance, the syndesmosis demonstrated 1.69° of dorsiflexion, 3.61° of eversion, and 3.95° of external rotation. Likewise, from mid-stance to heel-off, the syndesmosis presented 1.04° of plantarflexion, 4.95° of inversion, and 5.13° of internal rotation. CONCLUSION During the stance phase of normal gait, internal/external rotation and vertical motion play dominant roles in terms of rotation and translation, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstructing human push recovery reactions using a three dimensional under-actuated bipedal robot

This paper presents the ability of hybrid zero dynamics (HZD) feedback control method to reproduce human like movements for walking push recovery of an under-actuated 3D biped model. The balance recovery controller is implemented on a three-dimensional under-actuated bipedal model subjected to a push disturbance. The biped robot model is considered as a hybrid system with eight degrees of freed...

متن کامل

A reliable radiographic measurement for evaluation of normal distal tibiofibular syndesmosis: a multi-detector computed tomography study in adults

BACKGROUND Syndesmotic injury may be difficult to diagnose, and radiological evaluation is very important. The purpose of this study was to offer a series of reliable and repeatable normal tibiofibular syndesmosis parameters in diagnosing injuries of the syndesmosis. METHODS Multi-detector computed tomography (MDCT) and radiographs of the distal tibiofibular syndesmosis in 484 cases were retr...

متن کامل

From Passive Dynamic Walking to Passive Turning of Biped walker

Dynamically stable biped robots mimicking human locomotion have received significant attention over the last few decades. Formerly, the existence of stable periodic gaits for straight walking of passive biped walkers was well known and investigated as the notion of passive dynamic walking. This study is aimed to elaborate this notion in the case of three dimensional (3D) walking and extend it f...

متن کامل

Tightrope walking: A new technique in ankle syndesmosis fixation

Over the past few years, several studies have demonstrated favorable clinical outcomes and low complication rates using the ankle Tightrope® syndesmosis fixation system. The traditional surgical procedure of screw fixation for syndesmosis injury is associated with high complication rates of loosening, screw fracture, nonanatomic fixation, and postoperative syndesmotic diastasis. It is expected ...

متن کامل

Dynamically unstable syndesmosis injuries.

Distal tibiofibular syndesmosis injuries are complex injuries that often result in extended loss of playing time for athletes. Unstable syndesmosis injuries are uniformly reduced and stabilized by numerous methods. Controversy arises from syndesmosis injuries that are stable on stress radiographs but functionally unstable with loading of the ankle during athletic activity. The authors present a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery and research

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015