Hand-held syringe as a portable plastic pump for on-chip continuous-flow PCR: miniaturization of sample injection device.

نویسندگان

  • Wenming Wu
  • Kieu The Loan Trinh
  • Nae Yoon Lee
چکیده

On-chip continuous-flow polymerase chain reactions (PCRs) generally require peripheral apparatus such as a pump for injecting a sample liquid into the fluidic channel. This makes the overall instrumentation bulky, limiting integration. In this study, we propose a new scheme for injecting a sample employing a hand-held syringe as a portable plastic pump, and apply it to an on-chip continuous-flow PCR. In the proposed injection scheme, sample actuation was realized inside a highly gas-permeable and blunt-ended fluidic conduit connected to a hand-held plastic syringe filled with compressed air. In this system, the degree of air diffusion via the walls of the gas-permeable conduit becomes greater in the anterior (closer to the outlet) end of the sample plug than the posterior (closer to the inlet) end, because a relatively larger quantity of air is retained inside the syringe at the posterior end of the sample plug. This creates a pressure gradient at the inlet and outlet of the fluidic conduit and propels the sample forward toward the outlet. Preliminary experiments were performed for the quantitative analyses and evaluation of the proposed sample injection scheme using gas-permeable silicone tubes. As practical applications, a 230 bp gene fragment from a plasmid vector and the first 282 bp of the interferon-beta (IFN-β) promoter from a human genomic DNA were successfully amplified on a microdevice coupled with a hand-held syringe as a portable sample actuation device, greatly enhancing device portability for on-site analyses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent Progress in Lab-on-a-Chip Technology and Its Potential Application to Clinical Diagnoses

We present the construction of the lab-on-a-chip (LOC) system, a state-of-the-art technology that uses polymer materials (i.e., poly[dimethylsiloxane]) for the miniaturization of conventional laboratory apparatuses, and show the potential use of these microfluidic devices in clinical applications. In particular, we introduce the independent unit components of the LOC system and demonstrate how ...

متن کامل

Fabrication of Polymerase Chain Reaction Plastic Lab-on-a-Chip Device for Rapid Molecular Diagnoses

PURPOSE We aim to fabricate a thermoplastic poly(methylmethacrylate) (PMMA) Lab-on-a-Chip device to perform continuous- flow polymerase chain reactions (PCRs) for rapid molecular detection of foodborne pathogen bacteria. METHODS A miniaturized plastic device was fabricated by utilizing PMMA substrates mediated by poly(dimethylsiloxane) interfacial coating, enabling bonding under mild conditio...

متن کامل

غلظت‌سازی ترکیبات آلی فرار از مایعات خالص در فاز گازی

  Background and aims: Production of fixed concentration of vapors from pure liquid has many applications in laboratory and field studies of occupational health and toxicological research and also in calibration of air pollutant measurement devices of the workplaces. In this study, the advantages and disadvantages of different concentration generation methods were discussed. In addition two sel...

متن کامل

Bubble-free on-chip continuous-flow polymerase chain reaction: concept and application.

Bubble formation inside a microscale channel is a significant problem in general microfluidic experiments. The problem becomes especially crucial when performing a polymerase chain reaction (PCR) on a chip which is subject to repetitive temperature changes. In this paper, we propose a bubble-free sample injection scheme applicable for continuous-flow PCR inside a glass/PDMS hybrid microfluidic ...

متن کامل

Toward complete miniaturisation of flow injection analysis systems: microfluidic enhancement of chemiluminescent detection.

Conventional flow injection systems for aquatic environmental analysis typically comprise large laboratory benchscale equipment, which place considerable constraints for portable field use. Here, we demonstrate the use of an integrated acoustically driven microfluidic mixing scheme to enhance detection of a chemiluminescent species tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate-a common ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 137 4  شماره 

صفحات  -

تاریخ انتشار 2012