A Comparison of Optimal Operation of a Residential Fuel Cell Co-Generation System Using Clustered Demand Patterns Based on Kullback-Leibler Divergence
نویسندگان
چکیده
When evaluating residential energy systems like co-generation systems, hot water and electricity demand profiles are critical. In this paper, the authors aim to extract basic time-series demand patterns from two kinds of measured demand (electricity and domestic hot water), and also aim to reveal effective demand patterns for primary energy saving. Time-series demand data are categorized with a hierarchical clustering method using a statistical pseudo-distance, which is represented by the generalized Kullback-Leibler divergence of two Gaussian mixture distributions. The classified demand patterns are built using hierarchical clustering and then a comparison is made between the optimal operation of a polymer electrolyte membrane fuel cell co-generation system and the operation of a reference system (a conventional combination of a condensing gas boiler and electricity purchased from the grid) using the appropriately built demand profiles. Our results show that basic demand patterns are extracted by the proposed method, and the heat-to-power ratio of demand, the amount of daily demand, and demand patterns affect the primary energy saving of the co-generation system.
منابع مشابه
Optimal Sizing of a Reliable Hydrogen-based Stand-alone Wind-Fuel Cell System
A hybrid wind/ fuel cell generation system is designed to supply power demand. The aim of this design is to minimize the total cost of the hybrid system over an expected 20 years of operation. The optimization problem is solved aimed at providing a reliable supply for the consumer’s demand. The system consists of fuel cells, some wind units, some electrolyzers, a reformer, an anaerobic reactor ...
متن کاملModel Confidence Set Based on Kullback-Leibler Divergence Distance
Consider the problem of estimating true density, h(.) based upon a random sample X1,…, Xn. In general, h(.)is approximated using an appropriate in some sense, see below) model fƟ(x). This article using Vuong's (1989) test along with a collection of k(> 2) non-nested models constructs a set of appropriate models, say model confidence set, for unknown model h(.).Application of such confide...
متن کاملمدل فنی- اقتصادی سیستمهای Micro CHP با روشهای عملکردی مختلف
The growing worldwide demand for less polluting forms of energy has led to a renewed interest in the use of micro combined heat and power (CHP) technologies in the residential sector. The operation of micro CHP system results in simultaneous production of heat and power in a single household based on small energy conversion units. The heat produced may be used for space and water heating and po...
متن کاملEconomic Aspect of Fuel Cell Power as Distributed Generation
This paper presents an energy management strategy to supply residential load by hybrid fuel cell power plant (FCPP). Economical fuel cell (FC) model includes thermal load, local electrical load, operational cost, startup cost and different tariffs on electricity during the day hour is discussed. Several Strategies have been presented for supplying residential load (electrical and thermal loads...
متن کاملOn-grid and Off-grid Operation of Multi-Input Single-Output DC/DC Converter based Fuel Cell Generation System
This paper presents the modeling and simulation of a proton exchange membrane fuel cell (PEMFC) generation system for off-grid and on-grid operation and configuration. A fuel cell DG system consists of a fuel cell power plant, a DC/DC converter and a DC/AC inverter. The dynamic model for fuel cell array and its power electronic interfacing are presented also a multi-input single output (MISO) D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013