Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?

نویسندگان

  • K Wei
  • A R Jayaweera
  • S Firoozan
  • A Linka
  • D M Skyba
  • S Kaul
چکیده

OBJECTIVES This study sought to determine the basis of detection of stenosis by myocardial contrast echocardiography using venous administration of microbubbles and to define the relative merits of bolus injection versus continuous infusion. BACKGROUND The degree of video intensity (VI) disparity in myocardial beds supplied by stenosed and normal coronary arteries can be used to quantify stenosis severity after venous administration of microbubbles. However, the comparative merits of administering microbubbles as a bolus injection or continuous infusion has not been studied. METHODS Coronary stenoses of varying severity were created in either the left anterior descending or the left circumflex coronary artery in 18 dogs. Imagent US (AF0150) was given as a bolus injection in 10 dogs (Group I) and as both a bolus injection and a continuous infusion in 8 dogs (Group II). For bolus injections, peak VI was derived from time-intensity plots. During continuous infusion, microbubble velocity and microvascular cross-sectional area were derived from pulsing interval versus VI plots. Myocardial blood flow (MBF) was determined using radiolabeled microspheres. RESULTS During hyperemia, VI ratios from the stenosed versus normal beds correlated with radiolabeled microsphere-derived MBF ratios from those beds for both bolus injections (r = 0.81) and continuous infusion (r = 0.79). The basis for detection of stenosis common to both techniques was the decrease in myocardial blood volume distal to the stenosis during hyperemia. The advantage of continuous infusion over bolus injection was the abolition of posterior wall attenuation and the ability to quantify MBF. CONCLUSIONS Both bolus injection and continuous infusion provide quantitative assessment of relative stenosis severity. Compared with bolus injection, continuous infusion also allows quantification of MBF and data acquisition without attenuation of any myocardial bed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast echocardiography for myocardial perfusion imaging using intravenous agents: progress and promises.

AIMS This article is a convenient overview to assist the interested echocardiographist towards acquiring his own experience in the field of myocardial perfusion imaging using intravenous contrast agents. This goal is now pursued in many centres, since contrast echo holds the advantages of cardiac ultrasound (non-invasiveness, high spatial and temporal resolution, wide availability, use of non-i...

متن کامل

Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.

BACKGROUND Ultrasound can cause microbubble destruction. If microbubbles are administered as a continuous infusion, then their destruction within the myocardium and measurement of their myocardial reappearance rate at steady state will provide a measure of mean myocardial microbubble velocity. Conversely, measurement of their myocardial concentration at steady state will provide an assessment o...

متن کامل

Rapid detection of coronary artery stenoses with real-time perfusion echocardiography during regadenoson stress.

BACKGROUND Real-time myocardial contrast echocardiography permits the detection of myocardial perfusion abnormalities during stress echocardiography, which may improve the accuracy of the test in detecting coronary artery stenoses. We hypothesized that this technique could be used after a bolus injection of the selective A2A receptor agonist regadenoson to rapidly and safely detect coronary art...

متن کامل

Quantification of myocardial perfusion with myocardial contrast echocardiography during left atrial injection of contrast. Implications for venous injection.

BACKGROUND The purpose of this study was to determine whether myocardial perfusion can be quantified with myocardial contrast echocardiography using left atrial (LA) injection of contrast. METHODS AND RESULTS Based on a series of in vitro and in vivo experiments, the optimal dose of sonicated albumin microbubbles injected into the LA for establishing a linear relation between video intensity ...

متن کامل

Detection of coronary stenosis with myocardial contrast echocardiography using regadenoson, a selective adenosine A2A receptor agonist.

AIMS Regadenoson is comparable to adenosine in pharmacologic radionuclide stress tests but has not been studied with stress myocardial contrast echocardiography. This study assessed the haemodynamic profile and ability of regadenoson, a novel selective A(2A) receptor agonist, to detect coronary artery stenosis during myocardial contrast echocardiography. METHODS AND RESULTS Myocardial contras...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 1998