PURPOSE To investigate factors controlling the aberrations of the eye, including accommodation, wavelength, and the apodization of the optics of the eye by cone directional selectivity. METHODS We constructed a new implementation of the Spatially Resolved Refractometer (SRR). This is an instrument, based on the Scheiner principle, that allows the rapid psychophysical measurement of the complete wavefront aberrations of the eye. We have investigated both the reproducibility of the measurements, and the effect of static accommodation and wavelength on the wavefront aberrations of the eye. In addition we combined the wave front aberrations with cone photoreceptor directionality to compute the modulation transfer function of the eye, at the retinal level. RESULTS The SRR measurements were rapid (4 minutes per measurements, 12 minutes per patient) and reproducible. There are significant changes in wavefront quality with accommodation, with optimal image quality near the resting point of accommodation. Image quality for polychromatic (white) light is strongly affected by both longitudinal and transverse chromatic aberration. Finally, we find that incorporating the effects of cone directionality into the calculation of image quality can increase image quality by up to 50%. CONCLUSION Calculation of a simple "optimal surgical shape" for wave-front guided refractive surgery will depend on improved understanding of the interplay between the biological and physical properties of the eye.
منابع مشابه
Comparing laser ray tracing, the spatially resolved refractometer, and the Hartmann-Shack sensor to measure the ocular wave aberration.
PURPOSE To compare quantitatively three techniques to measure the optical aberrations of the human eye: laser ray tracing (LRT), the Hartmann-Shack wavefront sensor (H-S), and the spatially resolved refractometer (SRR). LRT and H-S are objective imaging techniques, whereas SRR is psychophysical. METHODS Wave aberrations were measured in two normal subjects with all three techniques implemente...
متن کاملInvestigating sources of variability of monochromatic and transverse chromatic aberrations across eyes
Schematic eye models have typically been used to explain the average monochromatic and chromatic imaging properties of the eye. Both monochromatic aberrations and transverse chromatic aberration are known to vary widely across subjects. However, to our knowledge, the ability of schematic eye models to predict these individual variations has not been tested experimentally. We used a spatially re...
متن کاملEffect of the polarization on ocular wave aberration measurements.
Measurement of the eye's wave aberrations has become fairly standard in recent years. However, most studies have not taken into account the possible influence of the polarization state of light on the wave aberration measurements. The birefringence properties of the eye's optical components, in particular corneal birefringence, can be expected to have an effect on the wave aberration estimates ...
متن کاملA new approach to the study of ocular chromatic aberrations
We measured the ocular wavefront aberration at six different visible wavelengths (between 450 and 650 nm) in three subjects, using a spatially resolved refractometer. In this technique, the angular deviation of light rays entering the pupil at different locations is measured with respect to a target viewed through a centered pupil. Fits of the data at each wavelength to Zernike polynomials were...
متن کاملMonochromatic aberrations in the accommodated human eye
The wave-front aberration of the human eye was measured for eight subjects using a spatially resolved refractometer (a psychophysical ray-tracing test). The eyes were undilated and presented with accommodative stimuli varying from 0 to -6 diopters. Monochromatic wave-front aberrations tend to increase with increasing levels of accommodation, although there are substantial individual variations ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2000