A NEW upgrade to the Zyoptix wavefront- guided refractive surgery system (Bausch&Lomb) greatly simplifies pre- operative examination and calculation of the ablation profile by removing the need for pupil dilatation during aberrometry

نویسنده

  • Erik Mertens
چکیده

A NEW upgrade to the Zyoptix wavefrontguided refractive surgery system (Bausch&Lomb) greatly simplifies preoperative examination and calculation of the ablation profile by removing the need for pupil dilatation during aberrometry and automatically incorporating wavefront data in the treatment algorithm, said Erik Mertens MD,Antwerp Eye Center,Antwerp, Belgium. The upgrades include a better computer for measurements with the Orbscan topographer and the Zywave aberrometer and new software.A wireless link allows direct data transfer of diagnostic measurements to the new updated laser treatment calculator, without the need for floppy discs. In addition, the system's software eliminates the need for pupil dilation by extrapolating wavefront measurements from eyes with undilated pupils, he noted. “When we do higher-order corrections we need to dilate the pupil in a lot of cases because otherwise we won't have enough information. But the problem with dilation is you can get dry eye and de-centred pupils and it gets much more difficult to do a good job. Now with the new software from Bausch&Lomb you can have a 10 per cent larger treatment zone than the pupil diameter during wavefront measurement,” Dr Mertens told the 11th ESCRS Winter Refractive Meeting. As a result, the new software makes it possible to perform wavefront-guided treatments with optical zones up to 7.1mm when the pupil size at the time of examination was only 6.5mm, he added. In addition, the system eliminates the need for pharmacological pupil dilation and removes the extreme pupil shift issues and other sources of variation caused by dilation process. It also creates the possibility for one-day procedures. Moreover, it enables speedier examinations, which provides increased comfort to the patient and improved patient throughput for the surgeon, Dr Mertens said. The system's new personalised nomogram automatically incorporates the influence of pre-operative factors, including lowerand higher-order aberrations into the laser ablation algorithm, he noted. “The problem is that when you are going to treat higher-order aberrations and the patient has a lot of positive spherical aberration and you do not take that into account in your refraction you will get an overcorrection.This program does that for you, you just do a very good subjective refraction and your higher-order aberration measurements with Zywave, click the advanced nomogram button, and it will give you the treatment algorithm and you don't have to do anything to correct it yourself,” he added.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Refractional results of LASIK retreatment with wavefront-guided ablation versus standard ablation].

PURPOSE To evaluate refractive outcomes of wavefront-guided LASIK (Zyoptix, Bausch & Lomb) versus standard LASIK (PlanoScan, Bausch & Lomb) in retreatment of primary LASIK for myopia and myopic astigmatism. METHODS A prospective, randomized trial with paired eye control of 74 eyes from 37 patients who underwent LASIK retreatment was performed. Each patient underwent retreatment using Zyoptix ...

متن کامل

Aberrations induced in wavefront-guided laser refractive surgery due to shifts between natural and dilated pupil center locations.

PURPOSE To determine the aberrations induced in wavefront-guided laser refractive surgery due to shifts in pupil center location from when aberrations are measured preoperatively (over a dilated pupil) to when they are corrected surgically (over a natural pupil). SETTING Center for Visual Science and Department of Ophthalmology, University of Rochester, Rochester, New York, USA. METHODS Shi...

متن کامل

Wavefront aberrometry in Cataract Surgery and Laser vision Correction

66 CataraCt & refraCtive Surgery today euroPe SePtember 2012 The Munnerlyn ablation profiles first used in laser vision correction did not respect the normal prolate shape of the cornea. As a result, these profiles induced aberrations that reduced patients’ quality of vision. In recent years, enhanced understanding and technological adaptation to address spherocylindrical refractive error and h...

متن کامل

Q-factor customized ablation profile for the correction of myopic astigmatism.

PURPOSE To compare the results of the Q-factor customized aspheric ablation profile with the wavefront-guided customized ablation pattern for the correction of myopic astigmatism. SETTING Institute for Refractive and Ophthalmic Surgery, Zurich, Switzerland. METHODS Thirty-five patients were enrolled in a controlled study in which the nondominant eye was treated with the Q-factor customized ...

متن کامل

Topography-guided laser refractive surgery.

PURPOSE OF REVIEW Topography-guided laser refractive surgery regularizes the front corneal surface irregularities to achieve the desired refractive outcome. This is particularly applicable in highly aberrated corneas, where wavefront aberrometry is often not possible. This article aims to review the recently published results of topography-guided ablations in normal regular corneas, highly aber...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007