Design and use of variable flip angle schedules in transient balanced SSFP subtractive imaging.
نویسندگان
چکیده
In subtractive imaging modalities, the differential longitudinal magnetization decays with time, necessitating signal-efficient scanning methods. Balanced steady-state free precession pulse sequences offer greater signal strength than conventional spoiled gradient echo sequences, even during the transient approach to steady state. Although traditional balanced steady-state free precession requires that each excitation pulse use the same flip angle, operating in the transient regimen permits the application of variable flip angle schedules that can be tailored to optimize certain signal characteristics. A computationally efficient technique is presented to generate variable flip angle schedules efficiently for any optimization metric. The validity of the technique is shown using two phantoms, and its potential is demonstrated in vivo with a variable angle schedule to increase the signal-to-noise ratio (SNR) in myocardial tissue. Using variable flip angles, the mean SNR improvement in subtractive imaging of myocardial tissue was 18.2% compared to conventional, constant flip angle, balanced steady-state free precession (P = 0.0078).
منابع مشابه
Variable Flip Angle Schedules for Detecting Prepared Longitudinal Magnetization in Snapshot Balanced SSFP
Introduction: Tissue characterization by MRI often involves the subtraction of images obtained with and without a preparation of the longitudinal magnetization (e.g. T2 preparation, arterial spin labeling, and diffusion preparation). Studies based on snapshot balanced steady state free precession (SSFP) typically hasten the approach to the steady state by using a brief catalyzation [1] and cons...
متن کاملMR ventriculocisternography by using 3D balanced steady-state free precession imaging: technical note.
This study investigated the effects of flip angle setting in 3D balanced steady-state free precession (SSFP) imaging on CSF-parenchyma contrast and section aliasing artifacts. Theoretical derivations indicated that the extent of section aliasing artifacts decreased as the flip angle was lowered, at the expense of a sacrifice in CSF-parenchyma contrast. Experimental data agreed closely with theo...
متن کاملTime Optimal VERSE Excitation for 3D Balanced SSFP Imaging
Figure 3. Coronal (top) and axial (bottom) views from a 3D acquisiton slightly above the heart. Images have 2x2x3 mm resolution. The coronal image shows the 4cm, TB=10 slab profile in vivo. The contrast is consistent across the slab, indicating a flat slab profile. The black level is 0 for these images. Introduction: Balanced steady-state free precession (SSFP) imaging (TrueFISP, FIESTA, balanc...
متن کاملIntrinsic fat saturation of TIDE with variable flip angles due to modified stop bands
D. Paul, M. Zaitsev, J. Hennig Diagnostic Radiology Medical Physics, University Hospital, Freiburg, Germany Introduction Balanced steady state free precession sequences (b-SSFP; also known as TrueFISP, FIESTA, balanced FFE ...) are widely used in cardiac and abdominal imaging. They typically result in image contrast determined by T2/T1 [1]. In order to suppress signal oscillations from onand of...
متن کاملVariable Flip Angle Steady State Free Precession Imaging for Reduction of SAR
Introduction Steady state free precession (SSFP) imaging is used in widespread applications such as breath-hold MRI examinations of the abdomen and cardiac due to its very high signal-sampling efficiency and good tissue contrast. SSFP imaging at a high static field strength of 3 T and greater often suffers from specific absorption rate (SAR) problems because a high flip angle and short repetiti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 63 2 شماره
صفحات -
تاریخ انتشار 2010