Perylene ligand wrapping G-quadruplex DNA for label-free fluorescence potassium recognition.

نویسندگان

  • Yuwei Hu
  • Dongxue Han
  • Qixian Zhang
  • Tongshun Wu
  • Fenghua Li
  • Li Niu
چکیده

A perylene ligand, N,N-bis-(1-aminopropyl-3-propylimidazol salt)-3,4,9,10-perylene tetracarboxylic acid diimide ligand (PDI), which consisted of π-conjugated perylene moiety and hydrophilic side chains with positively charged imidazole rings, was used to wrap G-quadruplex for fluorescence turn-on K(+) recognition. Electrostatic attraction between PDI's positively charged imidazole rings and DNA's negatively charged phosphate backbones enabled PDI to accumulate on DNA. Upon trapping K(+), these G-rich DNA sequences transitioned to G-quadruplex. Subsequently, PDI ligands wrapped G-quadruplex, in which the flat aromatic core of PDI ligand interacted with G-quartet through π-π stacking and the side chains were positioned in grooves through electrostatic interactions. Consequently, the interaction mode change and conformational transition from PDI stacked G-sequence to PDI wrapped G-quadruplex led to PDI fluorescence enhancement, which was readily monitored as the detection signal. This strategy excluded the sequence tagging step and exhibited high selectivity and sensitivity towards K(+) ion with the linear detection range of 10-150 nM. Besides, PDI ligands may hold diagnostic and therapeutic application potentials to human telomere and cancer cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A label-free fluorescence assay for potassium ions using riboflavin as a G-quadruplex ligand.

A label-free fluorescence K(+) assay was developed using riboflavin, a new G-quadruplex ligand, and a G-quadruplex sequence (PW17).

متن کامل

Graphene oxide amplified fluorescence anisotropy for label-free detection of potassium ion.

Fluorescence anisotropy (FA) has attracted considerable attention, but it has been rarely applied for the detection of small molecules and metal ions because they are too small to induce evident FA changes. Although some mass amplifying strategies have been developed, the recognition probes need to be covalently modified with the fluorescent dyes, which is complex and expensive. To overcome thi...

متن کامل

G-quadruplex-modulated fluorescence detection of potassium in the presence of a 3500-fold excess of sodium ions.

A label-free detection of K(+) was developed using G-quadruplex DNA (c-Myc) modulated fluorescence enhancement of tetrakis-(diisopropylguanidino) zinc phthalocyanine (Zn-DIGP). Upon the addition of increasing concentrations of potassium, a detection limit of 0.8 μM for K(+) was easily achieved. Comparative titrations using sodium, lithium, ammonium, transition metal, or alkali earth salts revea...

متن کامل

Label-free dual assay of DNA sequences and potassium ions using an aptamer probe and a molecular light switch complex.

A homogeneous assay is reported using Ru(phen)(2)(dppz)(2+) and a K(+)-binding aptamer for the selective and sensitive detection of a target oligonucleotide and potassium ions, based on reduction in fluorescence emission according to the formation of the G-quadruplex structure from the aptamer in the presence of K(+).

متن کامل

A selective and label-free strategy for rapid screening of telomere-binding Ligands via fluorescence regulation of DNA/silver nanocluster

Herein, the conformational switch of G-rich oligonucleotide (GDNA) demonstrated the obvious functional switch of GDNA which was found to significantly affect the fluorescence of the in-situ synthesized DNA/silver nanocluster (DNA-AgNC) in homogeneous solution. We envisioned that the allosteric interaction between GDNA and DNA-AgNC would be possible to be used for screening telomere-binding liga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2012