In patients with suspected acute stroke, CT perfusion-based cerebral blood flow maps cannot substitute for DWI in measuring the ischemic core
نویسندگان
چکیده
BACKGROUND Neuroimaging may guide acute stroke treatment by measuring the volume of brain tissue in the irreversibly injured "ischemic core." The most widely accepted core volume measurement technique is diffusion-weighted MRI (DWI). However, some claim that measuring regional cerebral blood flow (CBF) with CT perfusion imaging (CTP), and labeling tissue below some threshold as the core, provides equivalent estimates. We tested whether any threshold allows reliable substitution of CBF for DWI. METHODS 58 patients with suspected stroke underwent DWI and CTP within six hours of symptom onset. A neuroradiologist outlined DWI lesions. In CBF maps, core pixels were defined by thresholds ranging from 0%-100% of normal, in 1% increments. Replicating prior studies, we used receiver operating characteristic (ROC) curves to select thresholds that optimized sensitivity and specificity in predicting DWI-positive pixels, first using only pixels on the side of the brain where infarction was clinically suspected ("unilateral" method), then including both sides ("bilateral"). We quantified each method and threshold's accuracy in estimating DWI volumes, using sums of squared errors (SSE). For the 23 patients with follow-up studies, we assessed whether CBF-derived volumes inaccurately exceeded follow-up infarct volumes. RESULTS The areas under the ROC curves were 0.89 (unilateral) and 0.90 (bilateral). Various metrics selected optimum CBF thresholds ranging from 29%-32%, with sensitivities of 0.79-0.81, and specificities of 0.83-0.85. However, for the unilateral and bilateral methods respectively, volume estimates derived from all CBF thresholds above 28% and 22% were less accurate than disregarding imaging and presuming every patient's core volume to be zero. The unilateral method with a 30% threshold, which recent clinical trials have employed, produced a mean core overestimation of 65 mL (range: -82-191), and exceeded follow-up volumes for 83% of patients, by up to 191 mL. CONCLUSION CTP-derived CBF maps cannot substitute for DWI in measuring the ischemic core.
منابع مشابه
In Acute Stroke, Can CT Perfusion-Derived Cerebral Blood Volume Maps Substitute for Diffusion-Weighted Imaging in Identifying the Ischemic Core?
BACKGROUND AND PURPOSE In the treatment of patients with suspected acute ischemic stroke, increasing evidence suggests the importance of measuring the volume of the irreversibly injured "ischemic core." The gold standard method for doing this in the clinical setting is diffusion-weighted magnetic resonance imaging (DWI), but many authors suggest that maps of regional cerebral blood volume (CBV)...
متن کاملLimited reliability of computed tomographic perfusion acute infarct volume measurements compared with diffusion-weighted imaging in anterior circulation stroke.
BACKGROUND AND PURPOSE Diffusion-weighted imaging (DWI) can reliably identify critically ischemic tissue shortly after stroke onset. We tested whether thresholded computed tomographic cerebral blood flow (CT-CBF) and CT-cerebral blood volume (CT-CBV) maps are sufficiently accurate to substitute for DWI for estimating the critically ischemic tissue volume. METHODS Ischemic volumes of 55 patien...
متن کاملComparison of admission perfusion computed tomography and qualitative diffusion- and perfusion-weighted magnetic resonance imaging in acute stroke patients.
BACKGROUND AND PURPOSE Besides classic criteria, cerebral perfusion imaging could improve patient selection for thrombolytic therapy. The purpose of this study was to compare quantitative perfusion CT imaging and qualitative diffusion- and perfusion-weighted MRI (DWI and PWI) in acute stroke patients at the time of their emergency evaluation. METHODS Thirteen acute stroke patients underwent p...
متن کاملQuantitative assessment of core/penumbra mismatch in acute stroke: CT and MR perfusion imaging are strongly correlated when sufficient brain volume is imaged.
BACKGROUND AND PURPOSE Our purpose was to determine (1) the correlation between quantitative CT and MR measurements of infarct core, penumbra, and mismatch; and (2) whether the difference between these measurements would alter patient selection for stroke clinical trials. METHODS We studied 45 patients with acute middle cerebral artery stroke imaged a mean of 3.8 hours after onset (range, 0.4...
متن کاملCombined diffusion and perfusion MRI with correlation to single-photon emission CT in acute ischemic stroke. Ischemic penumbra predicts infarct growth.
BACKGROUND AND PURPOSE More effective imaging methods are needed to overcome the limitations of CT in the investigation of treatments for acute ischemic stroke. Diffusion-weighted MRI (DWI) is sensitive in detecting infarcted brain tissue, whereas perfusion-weighted MRI (PWI) can detect brain perfusion in the same imaging session. Combining these methods may help in identifying the ischemic pen...
متن کامل