Radiotoxicity in robotic radiosurgery: proposing a new quality index for optimizing the treatment planning of brain metastases
نویسندگان
چکیده
BACKGROUND As irradiated brain volume at 12 Gy (V12) is a predictor for radionecrosis, the purpose of the study was to develop a model for Cyberknife (CK) plans that is able to predict the lowest achievable V12 at a given tumor size and prescription dose (PD), and to suggest a new quality index regarding V12 for optimizing the treatment planning of brain metastases. METHOD In our model V12 was approximated as a spherical shell around the tumor volume. The radial distance between tumor surface and the 12 Gy isodose line was calculated using an approximation of the mean dose gradient in that area. Assuming a radially symmetrical irradiation from the upper half space, the dose distribution is given by the superposition of single fields. The dose profiles of a single field were derived by the measured off-center ratios (OCR) of the CK system. Using the calculated gradients of the sum dose profiles, minimal-V12 was estimated for different tumor sizes. The model calculation was tested using a phantom dataset and retrospectively applied on clinical cases. RESULTS Our model allows the prediction of a best-case scenario for V12 at a given tumor size and PD which was confirmed by the results of the isocentric phantom plans. The results of the non-isocentric phantom plans showed that an optimization of coverage caused an increase in V12. This was in accordance with the results of the retrospective analysis. V12 s of the clinical cases were on average twice that of the predicted model calculation. A good agreement was achieved for plans with an optimal conformity index (nCI). Re-planning of cases with high V12 showed that lower values could be reached by selecting smaller collimators and by allowing a larger number of total MU and more MU per beam. CONCLUSIONS V12 is a main parameter for assessing plan quality in terms of radiotoxicity. The index f12 defined as the ratio of V12 from the actual plan with the evaluated V12 from our model describes the conformity of an optimally possible V12 and thus can be used as a new quality index for optimizing treatment plans.
منابع مشابه
In silico assessment of the dosimetric quality of a novel, automated radiation treatment planning strategy for linac-based radiosurgery of multiple brain metastases and a comparison with robotic methods
BACKGROUND To appraise the dosimetric features and the quality of the treatment plan for radiosurgery of multiple brain metastases optimized with a novel automated engine and to compare with plans optimized for robotic-based delivery. METHODS A set of 15 patients with multiple brain metastases was selected for this in silico study. The technique under investigation is the recently introduced ...
متن کاملبررسی بقا بر اساس سیستم نمرهبندی GPA در مبتلایان به متاستازهای مغزی درمان شده با رادیوسرجری گامانایف
Abstract Background: This study was done to define the role of Graded Prognostic Assessment (GPA) score for predicting overall survival in patients diagnosed with brain metastases undergoing Gamma-knife radiosurgery. Materials and methods: Patients diagnosed with brain metastases who were candidates for Gamma-knife radiosurgery entered this cross sectional study between 2003 and 2011. Clin...
متن کاملEvaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm?
PURPOSE To investigate the feasibility of a novel dedicated treatment planning solution, to automatically target multiple brain metastases with a single isocenter and multiple inversely-optimized dynamic conformal arcs (DCA), and to benchmark it against the well-established multiple isocenter DCA (MIDCA) and volumetric modulated arc therapy (VMAT) approaches. MATERIAL AND METHODS Ten previous...
متن کاملHyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach
PURPOSE The HyperArc VMAT (HA-VMAT) planning approach was newly developed to fulfill the demands of dose delivery for brain metastases stereotactic radiosurgery. We compared the dosimetric parameters of the HA-VMAT plan with those of the conventional VMAT (C-VMAT). MATERIAL AND METHODS For 23 patients (1-4 brain metastases), C-VMAT and HA-VMAT plans with a prescription dose of 20-24 Gy were r...
متن کاملTransactions on Robotics and Automation 1 Planning for Camera - Guided Robotic
| Radiosurgery is a treatment for brain tumors and other lesions which employs a moving beam of photon radiation. In robotic radiosurgery, the radiation source is moved by a six degree-of-freedom robotic arm. A treatment planning system for robotic radiosurgery was developed. This planning system combines collision avoidance techniques and geometric algorithms for nding appropriate robot paths ...
متن کامل