Quantitative analysis of residual protein contamination of podiatry instruments reprocessed through local and central decontamination units

نویسندگان

  • Gordon WG Smith
  • Frank Goldie
  • Steven Long
  • David F Lappin
  • Gordon Ramage
  • Andrew J Smith
چکیده

BACKGROUND The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. METHODS The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. RESULTS Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). CONCLUSIONS Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decontamination of surgical instruments from prion proteins: in vitro studies on the detachment, destabilization and degradation of PrPSc bound to steel surfaces.

Effective reprocessing of surgical instruments ensuring elimination of inadvertent contamination with infectious agents causing transmissible spongiform encephalopathies (TSEs) is essential for the prevention of iatrogenic transmission of Creutzfeldt-Jakob disease (CJD) or its new variant (vCJD) from asymptomatic carriers. In a search for effective yet instrument-friendly and routinely applicab...

متن کامل

An evaluation of the infection control potential of a UV clinical podiatry unit

BACKGROUND Infection control is a key issue in podiatry as it is in all forms of clinical practice. Airborne contamination may be particularly important in podiatry due to the generation of particulates during treatment. Consequently, technologies that prevent contamination in podiatry settings may have a useful role. The aims of this investigation were twofold, firstly to determine the ability...

متن کامل

Plasma cleaning of dental instruments.

The theoretical risk of prion transmission via surgical instruments is of current public and professional concern. These concerns are further heightened by reports of the strong surface affinity of the prion protein, and that the removal of organic material by conventional sterilization is often inadequate. Recent reports of contamination on sterilized endodontic files are of particular relevan...

متن کامل

Residual protein levels on reprocessed dental instruments.

Reduction of the initial bioburden on instruments, prior to sterilization, is believed to reduce transmission risks of iatrogenic Creutzfeldt-Jakob disease. Endodontic files are used in the preparation of root canals and are likely to have close contact and become contaminated with neural material from branches of the maxillary and mandibular cranial nerves. This study examined methods used by ...

متن کامل

Improving the inspection and manual cleaning of dental instruments in a dental hospital

Within the dental hospital setting, it is a frequent occurrence to find residual cement contaminating instruments in a newly opened kit having undergone the decontamination cycle. Any instrument found to be contaminated then cannot be used, as the area underneath the cement is not sterile. This in itself has several repercussions. These include: cross-contamination, since there is a chance that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2011