Analytical performance of the i-STAT cardiac troponin I assay.

نویسندگان

  • Fred S Apple
  • MaryAnn M Murakami
  • Robert H Christenson
  • John L Campbell
  • Cary J Miller
  • Karl G Hock
  • Mitchell G Scott
چکیده

BACKGROUND This study determines the analytical characteristics of the i-STAT cardiac troponin I assay (cTnI; i-STAT, Princeton, NJ), a 10-min POC assay, designed to be performed at the bedside. METHODS Three different hospitals participated in a patient specimen and analytical validation study (n=186) for the i-STAT cTnI assay carried out in real time. A total of 186 whole blood specimens (lithium heparin) were collected from patients presenting with symptoms suggestive of acute coronary syndromes (ACS) for correlation studies as well as from 162 healthy subjects for reference interval determination. Factors studied included antibody specificity, detection limit, imprecision, linearity, assay specificity, sample type stability, interferences, reference limit determination and comparison vs. the Dade Stratus CS cTnI assay. RESULTS Total imprecision (CV) of 10% and 20% were seen at 0.09 and 0.07 microg/l, respectively. The detection limit was 0.02 microg/l. The 99th percentile reference limit was 0.08 microg/l. The assay was not affected by common interferents. An equimolar response within 5% was found for reduced and phosphorylated forms of TIC and IC complexes. Regression analysis for the i-STAT cTnI between whole blood and plasma specimens and for whole blood between the i-STAT and Stratus CS cTnI assays demonstrated slopes of 1.06 and 0.89, respectively. CONCLUSIONS The i-STAT cTnI assay is a sensitive and precise monitor of cTnI, poised for point-of-care/near bedside clinical utilization for triage, diagnostics and risk management of acute coronary syndrome patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac troponin assay classification by both clinical and analytical performance characteristics: a study on outcome prediction.

BACKGROUND Cardiac troponin assays have been classified according to whether they measure the 99th percentile concentration of a healthy reference population with imprecision (expressed as CV) of ≤10%, between 10% and 20%, or >20%. Assays in these categories have been deemed "guideline acceptable," "clinically usable," or "not acceptable," respectively. We compared four widely used "clinically ...

متن کامل

Comparison of ARCHITECT chemiluminiscent microparticle immunoassay for determination of Troponin I in serum with AXYM MEIA technology

Introduction: The aim of this study was determination of troponin I at serum using Architect (Abbott) and AxSYM System (Abbott). Troponin is regulatory subunit of the troponin complex associate with actin filament within muscle cells and it is a marker for diagnosis of myocardial damage. Methods: We used Architect STAT chemiluminescent microparticle immunoassay (CMIA) and AxSYM microparticle En...

متن کامل

Analysis of the relation between coping ways with stress and Cardiac Biomarker Troponin I in coronary heart disease patients

Introduction: Coping ways with stress in coronary heart disease patients can lead to significant changes in levels of Cardiac Biomarker Troponin I, but researchers had not explored it empirically. So, the main objective of this study was to identify the relationship between coping ways with stress and Cardiac Biomarker Troponin I and also, finding coping ways that predict changes in the concent...

متن کامل

سنجش مقادیر تروپونین ? قلبی در بیماران مبتلا به آمبولی حاد ریه و ارتباط آن با اختلال عملکرد بطن راست

Background and purpose: Right ventricular dysfunction is common in major pulmonary embolisms. The purpose of this study was to evaluate the prevalence and diagnostic utility of cardiac troponin I and also to identify patients with RV dysfunction in pulmonary embolism. Materials and methods: This study was conducted on 42 patients with pulmonary embolism in Ekbatan Hospital, in Hamedan city. ...

متن کامل

Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.

BACKGROUND The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinica chimica acta; international journal of clinical chemistry

دوره 345 1-2  شماره 

صفحات  -

تاریخ انتشار 2004