Contralateral transvenous left ventricular lead placement of implantable devices with pre-sternal tunnelling in chronically obstructed subclavian veins

نویسندگان

  • Praveen P. Sadarmin
  • Rajesh K. Chelliah
  • Jonathan Timperley
چکیده

Cardiac resynchronisation therapy (CRT) is a recognised therapy for the management of severe left ventricular dysfunction, advanced congestive cardiac failure (NYHA III or IV), ventricular dyssynchrony (either broad LBBB or mechanical dyssynchrony on echocardiography) and failure of optimal medical therapy to achieve improvement in clinical status. Upgrading right ventricular pacemakers or defibrillators to biventricular devices is common and we describe here, 2 such cases of biventricular upgrade with blocked venous access on the ipsilateral side and successful placement of left ventricular leads following pre-sternal tunnelling from the contralateral side.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.

A transvenous lead system for implantable defibrillators would obviate a surgical thoracotomy and reduce the morbidity and mortality associated with implantation. We evaluated the clinical performance of a new nonthoracotomy lead system that included a defibrillation lead in the coronary sinus. At the time of defibrillator implantation, transvenous defibrillation leads were inserted percutaneou...

متن کامل

Use of a single coil transvenous electrode with an abdominally placed implantable cardioverter defibrillator in children.

While transvenous defibrillator electrode placement avoiding a thoracotomy is preferable, electrode size, a large intercoil spacing, and the need for subclavicular device placement preclude this approach in most children. We investigated a single RV coil to an abdominally placed active can ICD device. Five children ages 8-16 years (weight 21-50 kg, mean 35 kg) underwent ICD placement. Placement...

متن کامل

Inadvertent Transarterial Lead Placement in the Left Ventricle and Aortic Cusp: Percutaneous Lead Removal with Carotid Embolic Protection and Stent Graft Placement

BACKGROUND/PURPOSE Transarterial lead implantation in the left ventricle or aorta is a rare complication. Percutaneous lead removal is associated with significant thromboembolic and bleeding risk. We present two cases of lead removal from the left ventricle via the left subclavian artery with concurrent carotid embolic protection followed by stent graft placement in the subclavian artery. MET...

متن کامل

Subcutaneous implantable cardioverter-defibrillator (S-ICD) for secondary prevention of sudden cardiac death

Implantation of a transvenous implantable cardioverter-defibrillator (ICD) is a recognized method of secondary prevention of sudden cardiac death [1]. In some patients with indications for such a device, circumstances may occur that render ICD implantation difficult or impossible. Implantation of a subcutaneous ICD (S-ICD), not requiring introduction of any elements into the cardiovascular syst...