Use of catheter-tip velocity--pressure transducer to evaluate left ventricular function in man: effects of intravenous propranolol.
نویسندگان
چکیده
A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat changes in stroke volume index, stroke work index, LV end-diastolic pressure, maximum blood flow velocity and acceleration, and maximum LV dP/dt were determined. Propranolol produced a decrease in maximum blood flow velocity (from 58 +/- 4.7 to 42 +/- 5.1 cm/sec, p less than 0.002), and acceleration (from 1181 +/- 130 to 847 +/- 117 cm/sec2, p less than 0.002, max dP/dt (from 1361 +/- 70 to 1146 +/- 63 mm Hg/sec, p less than 0.002), stroke volume index (from 47 +/- 3.0 to 38 +/- 3.2 ml/m2, p less than 0.002) and total stroke work index (from 702 +/- 33 to 603 +/- 44 mJ/m2 p less than 0.04), with little change in mean aortic pressure, peak systolic pressure and LV end-diastolic pressure. Depression in myocardial function was detectable within 1 minute after initiation of propranolol and persisted when negative chronotropic effects were eliminated by atrial pacing. The multisensor catheter technique allows rapid and safe detection of changes in cardiovascular function during propranolol administration in conscious man.
منابع مشابه
Use of Catheter-tip. Velocity-Pressure Transducer
A catheter-tip velocity transducer with two high-fidelity pressure manometers was used to evaluate the left ventricular (LV) hemodynamic effects of intravenous propranolol (10 mg). Nine patients without clinical evidence of heart failure were studied. Pulsatile ascending aortic blood flow velocity and pressure and LV pressure were measured continuously during drug administration. Beat-to-beat c...
متن کاملEffect of pacing-induced tachycardia and myocardial ischemia on ventricular pressure-velocity relationships in man.
Ventricular function was evaluated in 18 patients prior to left ventriculography and selective coronary arteriography. Simultaneous left ventricular pressure (catheter-tip manometer) and dP/dt were recorded at resting heart rates and during tachycardia induced by right atrial pacing. Pressure-velocity curves were constructed from which Vmax and maximum measured contractile element velocity (max...
متن کاملThe influence of preload and heart rate on Doppler echocardiographic indexes of left ventricular performance: comparison with invasive indexes in an experimental preparation.
We evaluated the ability of Doppler echocardiography to assess left ventricular performance in six open-chest dogs studied under various conditions. Intravenous infusions of nitroglycerin were used to vary preload, atrial pacing was used to control heart rate, and changes in inotropic state were induced by two different doses of dobutamine (5 and 10 micrograms/kg/min iv) and by administration o...
متن کاملMeasurement of left ventricular diameter in the dog by cardiac catheterization. Validation and physiologic meaningfulness of an ultrasonic technique.
A cylindrical ultrasonic transducer on a catheter tip lodged in the cleft between the free wall of the right ventricle and the interventricular septum provides an easily measured echo from the posteroinferior left ventricular epicardial surface. The sonic path represents a diameter of the left ventricle at approximately its largest cross-sectional area. Experiments in six dogs demonstrated that...
متن کاملThe evaluation of left ventricular function in man. A comparison of methods.
Comparisons of the sensitivities of parameters for assessing left ventricular performance in man were made in 38 patients. The parameters compared were the ejection fraction, ventriculographic contraction patterns, the left ventricular end-diastolic pressure, and the contractile indices including the contractile element velocity at 10 mm Hg (Vce 10) and maximal contractile element velocity (Vma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 61 5 شماره
صفحات -
تاریخ انتشار 1980