A comparison of seal in seven supraglottic airway devices using a cadaver model of elevated esophageal pressure.

نویسندگان

  • Sven Bercker
  • Willi Schmidbauer
  • Thomas Volk
  • Gottfried Bogusch
  • Hans Peter Bubser
  • Mario Hensel
  • Thoralf Kerner
چکیده

BACKGROUND Supraglottic airway devices are increasingly important in clinical anesthesia and prehospital emergency medicine, but there are only few data to assess the risk for aspiration. We designed this study to compare the seal of seven supraglottic airway devices in a cadaver model of elevated esophageal pressure. METHODS The classic laryngeal mask airway, laryngeal mask airway ProSeal, intubating laryngeal mask airway Fastrach, laryngeal tube, laryngeal tube LTS II, Combitube, and Easytube were inserted into unfixed human cadavers with an exposed esophagus that had been connected to a water column of 130 cm height. Slow and fast increases of esophageal pressure were performed and the water pressure at which leakage appeared was registered. RESULTS The Combitube, Easytube, and intubating laryngeal mask Fastrach withstood the water pressure up to more than 120 cm H2O. The laryngeal mask airway ProSeal, laryngeal tube, and laryngeal tube LTS II were able to block the esophagus until 72-82 cm H2O. The classic laryngeal mask airway showed leakage at 48 cm H2O, but only minor leakage was found in the trachea. Devices with an additional esophageal drain tube drained fluid sufficiently without pulmonary aspiration. CONCLUSIONS Concerning the risk of aspiration, the use of devices with an additional esophageal drainage lumen might be superior for use in patients with an increased risk of aspiration. The Combitube, Easytube, and intubating laryngeal mask Fastrach showed the best capacity to withstand an increase of esophageal pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Cadaver study of oesophageal insufflation with supraglottic airway devices during positive pressure ventilation in an obstructed airway.

BACKGROUND Supraglottic airway devices (SADs) play an increasing role in airway management in clinical anaesthesia and emergency medicine. Until now, no data exist concerning the extent of oesophageal insufflation when oropharyngeal leak pressures are exceeded. METHODS Laryngeal masks LMA-Supreme™ and LMA-ProSeal™, laryngeal tubes LTS-D and LTS II, Combitube™, and I-Gel were inserted into unf...

متن کامل

Pulmonary aspiration associated with supraglottic airways: Proseal laryngeal mask airway and I-Gel™

Corresponding author: Yoon-Hee Kim, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Chungnam National University School of Medicine, Munhwa-ro, Jung-gu, Daejeon 301-721, Korea. Tel: 82-42-280-7840, Fax: 82-42-280-7968, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creative...

متن کامل

Comparison of Five 2nd-Generation Supraglottic Airway Devices for Airway Management Performed by Novice Military Operators

OBJECTIVES Five different second-generation supraglottic airway devices, ProSeal LMA, Supreme LMA, i-gel, SLIPA, and Laryngeal Tube Suction-D, were studied. Operators were inexperienced users with a military background, combat lifesavers, nurses, and physicians. METHODS This was a prospective, randomized, single-blinded study. Devices were inserted in the operating room in low light condition...

متن کامل

A comparison between Laryngeal Tube Suction II Airway and Proseal Laryngeal Mask Airway in laparascopic surgery.

This was a prospective randomized study comparing the ease of insertion, haemodynamic changes, quality of airway seal, oxygenation and ventilation parameters and complications between Laryngeal Tube Suction II (LTS II) with Proseal Laryngeal Mask Airway (PLMA), both are supraglottic airway incorporated with gastric passage. Fifty-four ASA I and II patients were randomly allocated to receive eit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 106 2  شماره 

صفحات  -

تاریخ انتشار 2008