Rapid Hyperpolarized-Gas Lung Imaging using a Parallel-Spiral Acquisition with BOSCO reconstruction

نویسندگان

  • H. Tan
  • W. Chen
  • P. Hu
  • G. W. Miller
  • T. A. Altes
  • J. F. Mata
  • E. E. de Lange
  • G. D. Cates
  • R. F. Lee
  • C. H. Meyer
  • J. P. Mugler
چکیده

H. Tan, W. Chen, P. Hu, G. W. Miller, T. A. Altes, J. F. Mata, E. E. de Lange, G. D. Cates, R. F. Lee, C. H. Meyer, and J. P. Mugler III Electrical Engineering, University of Virginia, Charlottesville, VA, United States, Biomedical Engineering, University of Virginia, Charlottesville, VA, United States, now with GE Healthcare, now with Beth Israel Deaconess Medical Center, Department of Radiology, University of Virginia, Charlottesville, VA, United States, Physics, University of Virginia, Charlottesville, VA, United States, Princeton Neuroscience Institute, Princeton University, Princeton, NJ, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic spiral MRI of pulmonary gas flow using hyperpolarized (3)He: preliminary studies in healthy and diseased lungs.

An optimized interleaved-spiral pulse sequence, providing high spatial and temporal resolution, was developed for dynamic imaging of pulmonary ventilation with hyperpolarized (3)He, and tested in healthy volunteers and patients with lung disease. Off-resonance artifacts were minimized by using a short data-sampling period per interleaf, and gradient-fidelity errors were compensated for by using...

متن کامل

Comparison of Parallel Image Reconstruction Methods to Acquire High Resolution ADC-Tensor Images of 3He in Human Lungs

Introduction Many lung diseases, such as emphysema, leads to severe destruction of the lung’s alveoli walls. Determining the Apparent Diffusion Coefficient (ADC) of hyperpolarized He-gas in lungs is a proven method of non-invasive probing the integrity of the lung’s microstructure [Morb1]. Due to sophisticated configuration of small airways the diffusion in lungs is anisotropic and can be chara...

متن کامل

Free breathing hyperpolarized 3He lung ventilation spiral MR imaging.

OBJECTIVES Current clinical hyperpolarized He lung ventilation MR imaging protocols rely on the patient's ability to control inhalation and exhalation and hold their breath on demand. This is impractical for intensive care unit patients under ventilation or for pediatric populations under the age of 3 to 4 years. To address this problem, we propose a free-breathing protocol for hyperpolarized H...

متن کامل

Comparison of Different Parallel Imaging Reconstruction Methods for Hyperpolarized 3He MRI

Introduction: In the field of lung imaging using hyperpolarized He, the recent involvement of the array coil seems very promising. These techniques allow for a more efficient use of the polarization. The spatial or temporal resolution as well as the comfort of the investigated person directly benefit from this new progress. However, it is a combination of different complicated techniques. The d...

متن کامل

Imaging of lung ventilation and respiratory dynamics in a single ventilation cycle using hyperpolarized He-3 MRI.

PURPOSE To image respiratory dynamics and three-dimensional (3D) ventilation during inhalation, breath-hold, and exhalation for evaluation of obstructive lung disease using a single dose of hyperpolarized (HP) He-3 during MRI. MATERIALS AND METHODS A single 2D-3D projections inside Z encoding (PRIZE)-2D acquisition was performed that consisted of a rapid 2D radial acquisition phase during inh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008