Multimodal individualized concept of hemodynamic monitoring.

نویسندگان

  • Zsolt Molnar
  • Zsolt Szabo
  • Marton Nemeth
چکیده

PURPOSE OF REVIEW To discuss the pathophysiological rationale of advanced hemodynamic monitoring in the critically ill and also to highlight the importance of a multimodal, individualized approach. RECENT FINDINGS There are several clinical studies and animal experiments evaluating, which hemodynamic endpoint should be the best target during fluid management. Recent systematic reviews and meta-analyses also investigated the effects of advanced hemodynamic endpoints targeted hemodynamic management on outcome mainly in high-risk surgical patients. Although most of these studies report positive results, this knowledge does not seem to affect our everyday practice. According to large international surveys, most physicians still rely on inappropriate indices. One of the reasons could be that target values applied in these studies can be misleading in the individual patient. Therefore, we describe the concept of an individualized approach, in which normalizing the components of oxygen delivery are put in the context of the patients' individual response by evaluating components of oxygen consumption, and organ perfusion. SUMMARY Advanced hemodynamic monitoring-based management provides a number of benefits, which could be better tailored for the patients' actual needs by putting this into a multimodal, individualized approach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Multimodal Concept of Hemodynamic Stabilization

Hemodynamic instability often leads to hypoperfusion, which has a significant impact on outcome in both medical and surgical patients. Measures to detect and treat tissue hypoperfusion early by correcting the imbalance between oxygen delivery and consumption is of particular importance. There are several studies targeting different hemodynamic endpoints in order to investigate the effects of go...

متن کامل

Evaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring

Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...

متن کامل

Monitoring of Tissue Oxygenation: an Everyday Clinical Challenge

Purpose of review The aim of this article is to study the overview of pathophysiology and clinical application of central venous oxygen saturation monitoring in critically ill patients and during the perioperative period. Recent findings There are several clinical studies and animal experiments evaluating the effects of goal-directed hemodynamic stabilization on critically ill patients. Recen...

متن کامل

Providers and Patients Caught Between Standardization and Individualization: Individualized Standardization as a Solution; Comment on “(Re) Making the Procrustean Bed? Standardization and Customization as Competing Logics in Healthcare”

In their 2017 article, Mannion and Exworthy provide a thoughtful and theory-based analysis of two parallel trends in modern healthcare systems and their competing and conflicting logics: standardization and customization. This commentary further discusses the challenge of treatment decision-making in times of evidence-based medicine (EBM), shared decision-making and personalized medicine. From ...

متن کامل

Hemodynamic monitoring in acute heart failure.

Hemodynamic monitoring has moved in the last few years from being the holy grail of evaluating patients with acute heart failure to being all but extinct. Recent studies have not demonstrated any sustained benefits from right heart catheterization, and some studies have even suggested harm due to adverse events related to this invasive procedure. It is possible that this lack of efficacy is rel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Current opinion in anaesthesiology

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2017