Low magnetic moment PIN diodes for high field MRI surface coils.

نویسندگان

  • Pavel Voskoboynik
  • Ronald D Joos
  • W E Doherty
  • Ron B Goldfarb
چکیده

Positive-intrinsic-negative (PIN) silicon diodes are commonly used in magnetic resonance imaging (MRI) coils to perform active or passive blocking and detuning, or to disable circuit functions. However, diode packages with large magnetic moments are known to cause image artifacts in high field MRI systems. In this study, diode packages with low magnetic moment were designed by compensating components of ferromagnetic nickel and paramagnetic tungsten with diamagnetic silver. The new diodes have an initial positive susceptibility up to fields of 1 T and a negative susceptibility from 1 to 7 T. Their magnetic moments are one to two orders of magnitude smaller than those of standard diodes; moments as small as 20 nJ/T at 7 T were achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling Low Magnetic Moment PIN diodes for MR Scanner Applications

Ultra Low Magnetic Moment (ULM) PIN diodes cause the smallest possible magnetic artifacts in high field MR Imaging. Designers of MR scanners often use CAD packages to simulate their designs but there are no models available in these CAD packages to simulate these important devices until now. A new model for PIN diodes used in MR scanners is presented and is applicable for devices used in higher...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Dynamic Modeling of Low Magnetic Moment PIN Diodes for MR Scanner Applications

Ultra Low Magnetic Moment (ULM) PIN diodes cause the smallest possible magnetic artifacts in high field MR Imaging. Designers of MR scanners often use CAD packages to simulate their designs but up until now, there have been no models available that show the behavior of the PIN diode in its ON and OFF state as well as in the switching transition between states. A new model for PIN diodes used in...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Micro-Electromechanical Systems (MEMS) based RF-switches in MRI – a performance study

Modern Magnetic Resonance Imaging (MRI) systems permit parallel, spatial-encoded MRI (pMRI) and as such it is now possible to have up to 128 adjacent coil elements in a coil array [1]. Together with reduced imaging times, pMRI can significantly help to enhance the signal to noise ratio (SNR) over extended fields of view (FOV) [2]. However, a large number of channels subsequently create new tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 33 12  شماره 

صفحات  -

تاریخ انتشار 2006