Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.
نویسندگان
چکیده
BACKGROUND New-generation coronary stents that release zotarolimus or everolimus have been shown to reduce the risk of restenosis. However, it is unclear whether there are differences in efficacy and safety between the two types of stents on the basis of prospectively adjudicated end points endorsed by the Food and Drug Administration. METHODS In this multicenter, noninferiority trial with minimal exclusion criteria, we randomly assigned 2292 patients to undergo treatment with coronary stents releasing either zotarolimus or everolimus. Twenty percent of patients were randomly selected for repeat angiography at 13 months. The primary end point was target-lesion failure, defined as a composite of death from cardiac causes, any myocardial infarction (not clearly attributable to a nontarget vessel), or clinically indicated target-lesion revascularization within 12 months. The secondary angiographic end point was the extent of in-stent stenosis at 13 months. RESULTS At least one off-label criterion for stent placement was present in 66% of patients. The zotarolimus-eluting stent was noninferior to the everolimus-eluting stent with respect to the primary end point, which occurred in 8.2% and 8.3% of patients, respectively (P<0.001 for noninferiority). There were no significant between-group differences in the rate of death from cardiac causes, any myocardial infarction, or revascularization. The rate of stent thrombosis was 2.3% in the zotarolimus-stent group and 1.5% in the everolimus-stent group (P=0.17). The zotarolimus-eluting stent was also noninferior regarding the degree (+/-SD) of in-stent stenosis (21.65+/-14.42% for zotarolimus vs. 19.76+/-14.64% for everolimus, P=0.04 for noninferiority). In-stent late lumen loss was 0.27+/-0.43 mm in the zotarolimus-stent group versus 0.19+/-0.40 mm in the everolimus-stent group (P=0.08). There were no significant between-group differences in the rate of adverse events. CONCLUSIONS At 13 months, the new-generation zotarolimus-eluting stent was found to be noninferior to the everolimus-eluting stent in a population of patients who had minimal exclusion criteria. (ClinicalTrials.gov number, NCT00617084.)
منابع مشابه
Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials
OBJECTIVES To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. DESIGN Mixed treatment comparison meta-analysis. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (s...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کاملComparison of zotarolimus- and everolimus-eluting coronary stents: final 5-year report of the RESOLUTE all-comers trial.
BACKGROUND Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents. However, data comparing long-term safety and efficacy of zotarolimus- (ZES) and everolimus-eluting stents (EES) are limited. RESOLUTE all-comers (Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent fo...
متن کاملBaremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...
متن کاملNext-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V®)
Percutaneous coronary revascularization has been a mainstay in the management of coronary artery disease since its introduction in the late 1970s. Bare-metal stents and, more recently, first-generation drug-eluting stents (DES), such as sirolimus-eluting (Cypher) and paclitaxel-eluting stents (Taxus), have further improved results of percutaneous coronary intervention (PCI) by improving early r...
متن کاملThe prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: a substudy of the RESOLUTE All Comers Trial.
OBJECTIVES This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents. BACKGROUND The SXscore can identify patients treated with PCI who are at highest risk of adverse events. METHODS The SXscore was calculated prospectively in 2,033 of the 2,292 patie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The New England journal of medicine
دوره 363 2 شماره
صفحات -
تاریخ انتشار 2010