Commutability of Cytomegalovirus WHO International Standard in Different Matrices

نویسندگان

  • Sara Jones
  • Erika M. Webb
  • Catherine P. Barry
  • Won S. Choi
  • Klara B. Abravaya
  • George J. Schneider
  • Shiaolan Y. Ho
چکیده

Commutability of quantitative standards allows patient results to be compared across molecular diagnostic methods and laboratories. This is critical to establishing quantitative thresholds for use in clinical decision-making. A matrix effect associated with the 1st cytomegalovirus (CMV) WHO international standard (IS) was identified using the Abbott RealTime CMV assay. A commutability study was performed to compare the CMV WHO IS and patient specimens diluted in plasma and whole blood. Patient specimens showed similar CMV DNA quantitation values regardless of the diluent or extraction procedure used. The CMV WHO IS, on the other hand, exhibited a matrix effect. The CMV concentration reported for the WHO IS diluted in plasma was within the 95% prediction interval established with patient samples. In contrast, the reported DNA concentration of the CMV WHO IS diluted in whole blood was reduced approximately 0.4 log copies/ml, and values fell outside the 95% prediction interval. Calibrating the assay by using the CMV WHO IS diluted in whole blood would introduce a bias for CMV whole-blood quantitation; samples would be reported as having higher measured concentrations, by approximately 0.4 log IU/ml. Based on the commutability study with patient samples, the RealTime CMV assay was standardized based on the CMV WHO IS diluted in plasma. A revision of the instructions for use of the CMV WHO IS should be considered to alert users of the potential impact from the diluent matrix. The identification of a matrix effect with the CMV WHO IS underscores the importance of assessing commutability of the IS in order to achieve consistent results across methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A commutable cytomegalovirus calibrator is required to improve the agreement of viral load values between laboratories.

BACKGROUND Viral load testing for cytomegalovirus (CMV) is an important diagnostic tool for the management of transplant recipients and immunocompromised individuals; however, inconsistency among laboratories in quantitative measurements of viral load limits interinstitutional comparisons. These inconsistencies stem from the lack of assays cleared by the US Food and Drug Administration, the abs...

متن کامل

Development of a Sensitive Quantitative Competitive PCR Assay for Detection of Human Cytomegalovirus DNA

Accurate and rapid diagnosis of human cytomegalovirus (HCMV) disease in immunocompromised patients has remained as a challenge. Quantitative competitive PCR (QC-PCR) methods for detection of HCMV in these individuals have improved the positive and negative predictive values of PCR for diagnosis of HCMV disease. In this study we used QC-PCR assay, using a co-amplified DNA standard, to quantitate...

متن کامل

Gaps in the traceability chain of human growth hormone measurements.

BACKGROUND Human growth hormone (hGH) is measured for the diagnosis of secretion disorders. These measurements fall under the EU Directive 98/79/EC on in vitro diagnostic medical devices requiring traceability of commercial calibrator values to higher-order reference materials or procedures (Off J Eur Communities 1998 Dec 7;L 331:1-37). External quality assessment schemes show large discrepanci...

متن کامل

Commutability still matters.

Commutability is a property of a reference material such that values measured for that reference material and for representative clinical samples have the same relationship between 2, or more, measurement procedures for the same measurand (1, 2 ). Commutability is required when a reference material will be used as a common calibrator for clinical laboratory measurement procedures or will be use...

متن کامل

Commutability of two JCTLM-listed secondary reference materials for two commercial lithium assays.

Fig. 1. Regression analysis (regression line – continuous – and 95% prediction interval – dashed lines) to evaluate commutability of IRMM BCR-304 (triangle) and NIST SRM 956c (black circles) between direct potentiometry and colorimetry assays for serum lithium. Gray circles identify native serum samples. Commutability of two JCTLM-listed secondary reference materials for two commercial lithium ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2016