In vivo measurement of body composition of chickens using quantitative magnetic resonance.
نویسندگان
چکیده
Quantitative magnetic resonance (QMR) is a nuclear magnetic resonance-based method for measuring the fat, lean, and water content of the total body of the live animal. The purpose of this study was to evaluate the use of QMR for measuring the body composition of chickens while comparing QMR results to those obtained by dual x-ray absorptiometry (DXA) and chemical analysis (CA). A total of 191 birds were scanned live (nonanesthetized) by QMR, killed, and then scanned by DXA. The birds were Ross 708 broiler chickens and ranged in weight from 786 to 3,130 g. In addition, 48 of the carcasses were chemically analyzed for total body lipid, water, and ash content. Compared with CA, QMR underestimated the percentage of total body fat by 34% whereas DXA overestimated the percentage of fat by 50% (10.35 ± 3.35 by CA vs. 6.73 ± 3.90 by QMR and 15.55 ± 4.01 by DXA; P < 0.05). Both QMR and DXA measurements of percentage total body fat were highly correlated with the CA measurement (R(2) = 0.94 and 0.68, respectively). Both QMR and DXA estimates of total body water were close to the CA measurement (1,166 ± 277 g by CA vs. 1,214 ± 279 g by QMR and 1,217 ± 255 g by DXA; P > 0.05), with R(2) values of 0.90 and 0.91, respectively. Based on regression analysis, when prediction equations were applied to the entire group of birds, the QMR and DXA measurements of total body water and total body lean mass were in good agreement, with no significant difference (1,125 ± 244 g vs. 1,135 ± 246 g and 1,377 ± 311 g vs. 1,403 ± 309 g, respectively; P > 0.05) and highly correlated (R(2) = 0.97 for both). Likewise, the QMR measurement of total body fat agreed closely with that measured by DXA (164 ± 48 g and 167 ± 47 g, respectively) and was highly correlated (R(2) = 0.72). The results of this study demonstrate that with proper calibration, both QMR and DXA can provide accurate measurements of the body composition of chickens. The major advantage of the QMR method is that no anesthesia is required, thus facilitating the ease of measurement and repeated measurements.
منابع مشابه
A Method for Body Fat Composition Analysis in Abdominal Magnetic Resonance Images Via Self-Organizing Map Neural Network
Introduction: The present study aimed to suggest an unsupervised method for the segmentation of visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) in axial magnetic resonance (MR) images of the abdomen. Materials and Methods: A self-organizing map (SOM) neural network was designed to segment the adipose tissue from other tissues in the MR images. The segmentation of SAT and VA...
متن کاملComparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei
Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...
متن کاملBlood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملMeasurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers
Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Poultry science
دوره 90 8 شماره
صفحات -
تاریخ انتشار 2011